The value of temporary external lumbar CSF drainage in predicting the outcome of shunting on normal pressure hydrocephalus.
نویسندگان
چکیده
OBJECTIVE It has been reported that temporary external lumbar CSF drainage (ELD) is a very accurate test for predicting the outcome after ventricular shunting in patients with normal pressure hydrocephalus (NPH). However, only a limited number of patients have been studied for assessing the predictive accuracy of ELD. Therefore, the value of ELD in predicting the outcome after a ventriculoperitoneal shunt in patients with presumed NPH was assessed. METHODS All patients with presumed NPH were invited to participate in this study. Clinical assessment, MRI, and neuropsychological evaluation were followed by a lumbar CSF tap test consisting of removing 40 ml CSF. When this test resulted in marked clinical improvement of gait impairment, mental disturbances, or both, the patient was shunted without further tests. In patients with either questionable or no improvement after the CSF tap test, ELD was carried out. The value of ELD for predicting the outcome after shunting was calculated by correlating the results of ELD with that of ventriculoperitoneal shunting. RESULTS Between January 1994 and December 2000, 49 presumed NPH patients from three institutes were included. Forty three had idiopathic, and the remaining six had secondary NPH. Forty eight patients were shunted; 39 had an ELD of whom 38 completed the test. After 2 months 35 of the 48 (73%) shunted patients had improved. The predictive value of a positive ELD was 87% (95% confidence interval (95% CI) 62-98) and that of a negative ELD 36% (95% CI 17-59). In two patients serious test related complications (meningitis) occurred without residual deficit. CONCLUSION The study suggests that although the predictive value of a positive ELD is high, that of a negative ELD is deceptively low because of the high rate of false negative results. The costs and invasiveness of the test and the possibility of serious test related complications further limits its usefulness in managing patients with presumed NPH.
منابع مشابه
Treatment of Idiopathic Normal Pressure Hydrocephalus by Persian Medicine: A Case Report
Idiopathic normal pressure hydrocephalus (iNPH) is a chronic disease in adults. The standard treatment in this type of hydrocephalus is shunting which is accompanied by some complications and there is also uncertainty about response to treatment. Therefore, surgery is performed in only 10-20% of the cases with iNPH. Currently, oral acetazolamide and repetitive lumbar puncture for drainage of th...
متن کاملNormal pressure hydrocephalus: Diagnostic and predictive evaluationon
In typical cases, normal pressure hydrocephalus (NPH) manifests itself with the triad of gait disturbance, which begins first, followed by mental deterioration and urinary incontinence associated with ventriculomegaly (on CT or MRI) and normal cerebrospinal fluid (CSF) pressure. These cases present minor diagnostic difficulties and are the most likely to improve after shunting. Problems arise w...
متن کاملMagnetic resonance spectroscopic determination of a neuronal and axonal marker in white matter predicts reversibility of deficits in secondary normal pressure hydrocephalus.
BACKGROUND Normal pressure hydrocephalus (NPH) is considered to be a treatable form of dementia, because cerebrospinal fluid (CSF) shunting can lessen symptoms. However, neuroimaging has failed to predict when shunting will be effective. OBJECTIVE To investigate whether 1H (proton) magnetic resonance (MR) spectroscopy could predict functional outcome in patients after shunting. METHODS Neur...
متن کاملAn Automated, Gravity-driven CSF Drainage System Decreases Complications and Lowers Costs
BACKGROUND FlowSafeTM (BeckerSmith Medical, Irvine, CA, USA) is a novel, robotic, external lumbar drainage (ELD) system, which was designed to control cerebrospinal fluid (CSF) drainage, reduce complications, and decrease treatment costs. METHODS Forty-seven consecutive neurosurgical patients requiring ELD were treated using the FlowSafe system. RESULTS In 39 of 40 patients with traumatic ...
متن کاملTemporary Lumbar Subcutaneous Cerebrospinal Fluid Shunt Placement in Pediatric Patient: A Technical Note.
BACKGROUND We report the technical aspects of lumbar subcutaneous cerebrospinal fluid (CSF) shunt for temporary CSF drainage that may be an alternative strategy to lumbar catheter placement with external drainage system. CASE DESCRIPTION A 7 years and nine-month old boy with developmental delay, intermittent episodes of agitation, and combination of myoclonic and generalized tonic clonic seiz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neurology, neurosurgery, and psychiatry
دوره 72 4 شماره
صفحات -
تاریخ انتشار 2002