Measurement Of Neuromagnetic Brain Function In Pre-school Children With Custom Sized MEG

نویسندگان

  • Graciela Tesan
  • Blake W. Johnson
  • Melanie Reid
  • Rosalind Thornton
  • Stephen Crain
چکیده

Magnetoencephalography is a technique that detects magnetic fields associated with cortical activity [1]. The electrophysiological activity of the brain generates electric fields - that can be recorded using electroencephalography (EEG)- and their concomitant magnetic fields - detected by MEG. MEG signals are detected by specialized sensors known as superconducting quantum interference devices (SQUIDs). Superconducting sensors require cooling with liquid helium at -270 degrees C. They are contained inside a vacumm-insulated helmet called a dewar, which is filled with liquid. SQUIDS are placed in fixed positions inside the helmet dewar in the helium coolant, and a subject's head is placed inside the helmet dewar for MEG measurements. The helmet dewar must be sized to satisfy opposing constraints. Clearly, it must be large enough to fit most or all of the heads in the population that will be studied. However, the helmet must also be small enough to keep most of the SQUID sensors within range of the tiny cerebral fields that they are to measure. Conventional whole-head MEG systems are designed to accommodate more than 90% of adult heads. However adult systems are not well suited for measuring brain function in pre-school chidren whose heads have a radius several cm smaller than adults. The KIT-Macquarie Brain Research Laboratory at Macquarie University uses a MEG system custom sized to fit the heads of pre-school children. This child system has 64 first-order axial gradiometers with a 50 mm baseline[2] and is contained inside a magnetically-shielded room (MSR) together with a conventional adult-sized MEG system [3,4]. There are three main advantages of the customized helmet dewar for studying children. First, the smaller radius of the sensor configuration brings the SQUID sensors into range of the neuromagnetic signals of children's heads. Second, the smaller helmet allows full insertion of a child's head into the dewar. Full insertion is prevented in adult dewar helmets because of the smaller crown to shoulder distance in children. These two factors are fundamental in recording brain activity using MEG because neuromagnetic signals attenuate rapidly with distance. Third, the customized child helmet aids in the symmetric positioning of the head and limits the freedom of movement of the child's head within the dewar. When used with a protocol that aligns the requirements of data collection with the motivational and behavioral capacities of children, these features significantly facilitate setup, positioning, and measurement of MEG signals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of brain function in pre-school children using a custom sized whole-head MEG sensor array.

OBJECTIVE Conventional whole-head MEG systems have fixed sensor arrays designed to accommodate most adult heads. However arrays optimised for adult brain measurements are suboptimal for research with the significantly smaller heads of young children. We wished to measure brain activity in children using a novel whole-head MEG system custom sized to fit the heads of pre-school-aged children. M...

متن کامل

Face-sensitive brain responses measured from a four-year-old child with a custom-sized child MEG system

BACKGROUND Previous magnetoencephalography (MEG) studies have failed to find a facesensitive, brain response-M170 in children. If this is the case, this suggests that the developmental trajectory of the M170 is different from that of its electrical equivalent, the N170. We investigated the alternative possibility that the child M170 may not be detectable in conventional adult-sized MEG systems....

متن کامل

Altered brain connectivity in 3-to 7-year-old children with autism spectrum disorder☆☆☆

Autism spectrum disorder (ASD) is often described as a disorder of aberrant neural connectivity and/or aberrant hemispheric lateralization. Although it is important to study the pathophysiology of the developing ASD cortex, the physiological connectivity of the brain in young children with ASD under conscious conditions has not yet been described. Magnetoencephalography (MEG) is a noninvasive b...

متن کامل

Neuromagnetic Vistas into Typical and Atypical Development of Frontal Lobe Functions

The frontal lobes are involved in many higher-order cognitive functions such as social cognition executive functions and language and speech. These functions are complex and follow a prolonged developmental course from childhood through to early adulthood. Magnetoencephalography (MEG) is ideal for the study of development of these functions, due to its combination of temporal and spatial resolu...

متن کامل

Magnetoencephalography Detection of High-Frequency Oscillations in the Developing Brain

Increasing evidence from invasive intracranial recordings suggests that the matured brain generates both physiological and pathological high-frequency signals. The present study was designed to detect high-frequency brain signals in the developing brain using newly developed magnetoencephalography (MEG) methods. Twenty healthy children were studied with a high-sampling rate MEG system. Function...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 65  شماره 

صفحات  -

تاریخ انتشار 2010