Ocular microtremor: a tool for measuring depth of anaesthesia?
نویسندگان
چکیده
Ocular microtremor (OMT) is a fine high frequency tremor of the eyes caused by extra-ocular muscle activity stimulated by impulses emanating in the brain stem. Several studies have shown that the frequency of this tremor is reduced in patients whose consciousness is reduced by anaesthesia or head injury. Therefore, OMT may possibly be used to determine depth of anaesthesia. Twenty-two unpre-medicated subjects undergoing surgery with general anaesthesia were studied. OMT activity was measured at admission using the open eye piezoelectric strain gauge technique. Anaesthesia was induced with propofol using a target controlled infusion delivery system (Diprifusor). OMT activity was then recorded at predicted plasma propofol concentrations of 1, 2, 3 and 5 microg ml(-1). The patient's level of consciousness (response to command or stimulation) was assessed after each OMT measurement. OMT activity was reduced progressively at predicted plasma concentrations of propofol of I and 2 microg ml(-1) and then plateaued between 3 and 5 microg ml(-1). There was a significant difference between the last awake OMT recording and the first recording at loss of consciousness (P < 0.001). OMT recording holds promise as a practical indicator of the depth of anaesthesia.
منابع مشابه
Speckle interferometric sensor to measure low-amplitude high frequency Ocular Microtremor (OMT)
Ocular microtremor (OMT) is a physiological high frequency (up to 150Hz) low amplitude (150-2500nm) involuntary tremor of the human eye. It is one of the three fixational ocular motions described by Adler and Fliegelman in 1934 as well as microsaccades and drift. Clinical OMT investigations to date have used eye-contacting piezoelectric probes or piezoelectric strain gauges. Before contact can ...
متن کاملOcular microtremor measurement using laser-speckle metrology.
We describe a novel, noninvasive measurement approach for recording a small involuntary tremor of the eye known as ocular microtremor. The method is based on measuring out-of-plane angular displacements of a target by using laser-speckle correlation of images recorded in the Fourier plane of a lens. The system has a dynamic range of 4 to 5000 μrad, resolution of 4 μrad, and a bandwidth of 250 H...
متن کاملDominant frequency content of ocular microtremor from normal subjects
Ocular microtremor (OMT) is a high frequency tremor of the eyes present during fixation and probably related to brainstem activity (Coakley, D. (1983). Minute eye movement and brain stem function. CRC Press, FL.). Published observations on the frequency of OMT have varied widely. Ocular microtremor was recorded in 105 normal healthy subjects using the Piezoelectric strain gauge technique. The d...
متن کاملتاثیر پروپوفول در جلوگیری از افزایش فشار چشم بدنبال تزریق سوکسینیل کولین و لوله گذاری نای
Background and purpose: Penetrating eye injury is one of the most frequent trauma admitted in ophtalmological emergency rooms. The major concern when treating such a trauma is increased intra-ocular pressure and vitreous loss as a side effect of Succinylcholine and endotracheal intubation with no appropriate substitute drug available yet. This study is aimed to determine whether the use of...
متن کاملPREDICTIVE MODELS OF THE DOMINANT PERIOD OF SITE USING ARTIFICIAL NEURAL NETWORK AND MICROTREMOR MEASUREMENTS: APPLICATION TO URMIA, IRAN
Direct drilling method and the use of microtremor studies are among the most commonly used available methods utilized to estimate dynamic parameters for a site. One of the most important parameters is the dominant period of the site whose estimation plays a pivotal role in seismic hazard mitigation. The conventional models obtained are not capable of estimating the parameters that govern the se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 86 4 شماره
صفحات -
تاریخ انتشار 2001