An interlaboratory study of the determination of digoxin by immunoassay.

نویسندگان

  • D M Fast
  • W H Hannon
  • C A Burtis
  • D D Bayse
چکیده

We conducted a voluntary survey of laboratories and manufacturers to assess the current quality of analytical assays for serum digoxin. More than 300 clinical laboratories and 18 manufacturers responded, giving data on methods, instruments, computational procedures, and results for five survey samples. We sorted the analytical data to provide statistical information on the grand mean values separately for manufacturers and clinical laboratories, the frequency distribution of all reported values, and the mean values by method of interpolation and algorithms used for linear transformation. There was no statistical difference (alpha = 0.05) between the means for each specimen as determined by the kit manufacturers as a group and the clinical laboratories as a group.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra- and interlaboratory sources of imprecision in drug measurements by different techniques.

We compared the intra- and interlaboratory precision of seven techniques used to measure eight antiepileptic drugs, digoxin, and theophylline by using data from the international Healthcontrol external quality-assessment scheme. Scheme participants were supplied blind with 6 or 12 sets of duplicate lyophilized serum samples. Each set contained different drug concentrations, and duplicates were ...

متن کامل

Effect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay.

Determination of digoxin by fluorescence polarization immunoassay (FPIA) with the Abbott "TDx" is significantly influenced by the concentration of total serum protein. Each 10 g/L increase in serum protein results in an 8% decrease in measured digoxin. Studies with [3H]digoxin confirmed that digoxin binds to the protein pellet during the trichloroacetic acid precipitation step before the immuno...

متن کامل

Cross-reactivity of anti-digoxin antibodies with digitoxin depends on tracer structure.

The most common methods for measuring digoxin concentrations in serum are immunoassays. The prerequisite for exact determination of the digoxin value is an antibody that specifically binds digoxin. Because digitoxin differs from digoxin only in the C-12 hydroxy group, it is difficult to obtain anti-digoxin antibodies that do not cross-react with this compound. During the development of a fluore...

متن کامل

Evaluation of enzyme-multiplied immunoassay technique (EMIT) for determination of serum digoxin.

Sixty-seven digoxin-containing sera were analyzed by both radioimmunoassay and EMIT. After some important modifications of the EMIT method, agreement between the two methods was very good. Reproducibility of the EMIT assay was excellent; daily variations in values found for control sera were quite small, and recovery of added digoxin was good. Slight hemolysis hadnegligible effects, but highly ...

متن کامل

Inspection of Digoxin level in cardiac heart failure patients refer to Taemin Ejtemai and Shohadaye Ashaer clinic

Background: Heart failure is one of the common cardiovascular diseases and digoxin has the positive effect on it. But unfortunately in spite of its positive effect on heart failure therapeutic and toxic level of it in patients is different and close to each other. The aim of this research was determination of digoxin serum level in failur heart patients. Materials and methods: In this cros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 1980