Assessment of cardiac function using multidetector row computed tomography.

نویسندگان

  • Sarwar H Orakzai
  • Raza H Orakzai
  • Khurram Nasir
  • Matthew J Budoff
چکیده

In patients with suspected or documented heart disease, a precise quantitative and qualitative assessment of cardiac function is critical for clinical diagnosis, risk stratification, management and prognosis. Cardiac CT is increasingly being used in diagnosis of coronary artery disease. Initially multi-detector row computed tomography (MDCT) was used chiefly for detecting coronary artery stenosis and assessment of cardiac morphology. Electron beam computed tomography has been shown to provide a highly accurate ejection fraction (+/-1%), with 50 ms image acquisition per image. Retrospective electrocardiographic gating allows for image reconstruction in any phase of the cardiac cycle. Thus, end systolic and end diastolic images can be produced to assess ventricular volumes and function. Despite lower temporal resolution than electron beam computed tomography, the ability of MDCT to assess ejection fraction is preserved. In the assessment of cardiac function, MDCT has been shown to be in good agreement with echocardiography, cineventriculography, single photon emission computed tomography and magnetic resonance imaging. The fast technical development of scanner hardware along with multisegmental image reconstruction has led to rapid improvement of spatial and temporal resolution and significantly faster cardiac scans. The same data that is acquired for MDCT angiography can also be used for evaluation of cardiac function. Considering contrast media application, radiation exposure, and limited temporal resolution, MDCT solely for analysis of cardiac function parameters seems not reasonable at the present time. However, because the data is already obtained during coronary evaluation, the combination of noninvasive coronary artery imaging and assessment of cardiac function with MDCT is a suitable approach to a conclusive cardiac workup in patients with suspected coronary artery disease. MDCT seems suitable for assessment of cardiac function by MDCT when results are held in comparison to magnetic resonance imaging as the reference standard. Given the radiation dose and contrast requirement, referring a patient to MDCT only for evaluation of function is not warranted, but rather adds important clinical information to the already acquired data during retrospective triggering for MDCT angiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ECG-gated multidetector-row computed tomography in the assessment of left ventricular function

An accurate quantitative and qualitative assessment of cardiac function is critical for clinical diagnosis, risk stratification, management and prognosis in patients with suspected or documented heart disease. Magnetic resonance, owing to its excellent temporal and spatial resolution, is currently considered a reference standard in the assessment of cardiac function. Multidetector-row computed ...

متن کامل

Multidetector-row computed tomography angiography for the diagnosis of anomalous pulmonary venous drainage: an initial experiment* Angiotomografia com múltiplos detectores no diagnóstico de drenagem venosa pulmonar anômala: experiência inicial

OBJECTIVE: We aimed to determine if multidetector-row computed tomography angiography is an effective and non-invasive method for diagnosing anomalous pulmonary venous drainage. MATERIALS AND METHODS: We performed a retrospective review of 2905 cases from July 2003 to November 2007 in which cardiac multidetector-row computed tomography was used. Of the cases, 393 evaluated congenital cardiopath...

متن کامل

Comparison of cardiac function and coronary angiography between conventional pigs and micropigs as measured by multidetector row computed tomography

Pigs are the most likely source animals for cardiac xenotransplantation. However, an appropriate method for estimating the cardiac function of micropigs had not been established. Computed tomography (CT) analysis aimed at estimating cardiac function and assessing the coronary arteries has not been carried out in micropigs. This study determined the feasibility of evaluating cardiac function in ...

متن کامل

Multiple atrial septal defects in multidetector-row computed tomography.

A 70-year-old-man was referred to our hospital for percutaneous closure of a secundum atrial septal defect (ASD). His transthoracic echocardiography (TTE) showed 2 left-to-right ASDs with a pulmonary/systemic flow ratio (Q p/Q s) of 1.89 and normal left ventricular function. Cardiac computed tomography (CT) using 320-detector row CT (Aquilion ONE VISION edition, Toshiba Medical Systems, Tokyo, ...

متن کامل

Discussion. Application of multidetector-row computed tomography in propeller flap planning.

BACKGROUND The propeller flap is defined as (1) being island-shaped, (2) having an axis that includes the perforators, and (3) having the ability to be rotated around an axis. The advantage of the propeller flap is that it is a pedicle flap that can be applied to cover defects located at the distal ends of the extremities. The specific aims of the authors' study were (1) to evaluate the usefuln...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of computer assisted tomography

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 2006