Impaired flow-mediated dilation and risk of restenosis in patients undergoing coronary stent implantation.

نویسندگان

  • Giuseppe Patti
  • Vincenzo Pasceri
  • Rosetta Melfi
  • Costanza Goffredo
  • Massimo Chello
  • Andrea D'Ambrosio
  • Rosamaria Montesanti
  • Germano Di Sciascio
چکیده

BACKGROUND Impaired endothelial function is a key event in the atherosclerosis process and predicts future cardiovascular events in subjects with and without coronary artery disease (CAD). We performed the first prospective study evaluating whether early measurement of brachial artery endothelium-dependent dilation (flow-mediated dilation [FMD]) after coronary stenting could predict occurrence of in-stent-restenosis. METHODS AND RESULTS The study population included 136 patients with single-vessel CAD undergoing percutaneous coronary intervention (PCI) with stenting and at least 6 months of follow-up. All patients underwent ultrasound detection of brachial artery reactivity 30 days after PCI; FMD was investigated before and after 5 minutes of occlusion of the brachial artery, and nitroglycerin-mediated dilation was investigated before and after administration of sublingual nitrates. Clinical in-stent restenosis was demonstrated in 20 patients (15%), whereas 116 patients (85%) remained free of signs or symptoms of recurrent ischemia. FMD was significantly impaired in patients with restenosis versus those without restenosis (percent diameter variation 4.6+/-5.8% versus 9.5+/-6.6%, P=0.002); moreover, 4% of patients with FMD > or =7% (median value) developed in-stent restenosis versus 28% of those with FMD <7% (P=0.0001). On multivariate analysis, FMD was the strongest predictor of restenosis (OR 4.5, 95% CI 2.4 to 12.0); conversely, nitroglycerin-mediated dilation did not independently predict the risk of restenosis (OR 2.4, 95% CI 0.8 to 6.3). CONCLUSIONS This is the first prospective study indicating that impaired FMD independently predicts occurrence of in-stent restenosis in patients undergoing PCI. Early evaluation of endothelial function after stenting may represent a useful screening tool to stratify patients according to future risk of restenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prognostic significance of endothelial dysfunction in patients undergoing percutaneous coronary intervention in the era of drug-eluting stents

BACKGROUND Endothelial function is a prognostic predictor in patients undergoing percutaneous coronary intervention (PCI). However, in an era with widespread use of drug-eluting stents, the clinical relevance of endothelial dysfunction on restenosis in patients undergoing PCI has not been fully evaluated. METHODS This study included 80 patients with stable angina pectoris. Flow-mediated dilat...

متن کامل

Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve.

BACKGROUND There is controversy regarding the immediate and long-term effects of PTCA on the coronary flow reserve. METHODS AND RESULTS A total of 54 patients with 1-vessel disease and normal left ventricular function were studied after balloon angioplasty (n=34) or stent implantation (n=20). Distal coronary blood flow velocity reserve (CFR) was defined as the ratio of adenosine-induced hyper...

متن کامل

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

INtimal hyPerplasia evAluated by oCT in de novo COROnary lesions treated by drug-eluting balloon and bare-metal stent (IN-PACT CORO): study protocol for a randomized controlled trial

BACKGROUND Neointimal hyperplasia plays a pivotal role in the pathogenesis of in-stent restenosis in patients undergoing percutaneous coronary interventions. Drug-eluting balloons are a promising tool to prevent restenosis after coronary angioplasty. Moreover, an increased knowledge of the pathophysiology of restenosis my help improve therapeutic strategies. METHODS/DESIGN We present the desi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 111 1  شماره 

صفحات  -

تاریخ انتشار 2005