A Physiological Dynamic Testing Machine for the Elbow Joint
نویسندگان
چکیده
BACKGROUND The aim of our study was to develop a test setup combining realistic force transmission with physiological movement patterns at a frequency that mimicked daily use of the elbow, to assess implants in orthopedic joint reconstruction and trauma surgery. METHODS In a multidisciplinary approach, an in vitro biomechanical testing machine was developed and manufactured that could simulate the repetitive forceful movement of the human elbow joint. The construction involved pneumatic actuators. An aluminum forearm module enabled movements in 3 degrees of freedom, while motions and forces were replicated via force and angular sensors that were similar to in vivo measurements. RESULTS In the initial testing, 16 human elbow joint specimens were tested at 35 Nm in up to 5000 cycles at a range of 10° extension to 110° flexion. The transmitted forces led to failure in 9 out of the 16 tested specimens, significantly more often in females and small specimens. CONCLUSIONS It is possible to construct a testing machine to simulate nearly physiological repetitive elbow motions. The prototype has a number of technical deficiencies that could be modified. When testing implants for the human elbow with cadaver specimens, the specimen has to be chosen according to the intended use of the implant under investigation.
منابع مشابه
In vivo fluoroscopic kinematography of dynamic radio-ulnar incongruence in dogs
Aim of the study was to investigate dynamic radio-ulnar incongruence (dRUI) in the canine elbow joint comparing orthopedic healthy and dysplastic dogs in a prospective in vivo study design. In 6 orthopedic sound elbow joints (5 dogs, median age 17 months & mean body weight 27.9 kg) and 7 elbow joints with medial coronoid disease (6 dogs, median age 17.5 months & mean body weight 27.6 kg) 0.8 mm...
متن کاملKinematics and Dynamic Modelling of the Human Shoulder
This paper deals with kinematics and dynamics of the human shoulder in order to obtain the workspace related to the reachability of the wrist and applications to determine load for the wheelchair. The model contains six revolute degrees of freedom (D.O.F), two in costoclavicular and three in the shoulder joint and one in the elbow joint, while a six D.O.F model was developed according to given ...
متن کاملElbow Stiffness Secondary to Elbow Joint Osteoid Osteoma, a Diagnostic Dilemma
We present a 23-year-old man with distal humerus osteoid osteoma referring to our hospital with pain and progressive stiffness. The patient has been suffering from the disease for two years without a certain diagnosis. The radiographies of elbow did not reveal the pathology but further CT scan and MRI studies demonstrated the tumor. The en block resection of the tumor resolved the pain immediat...
متن کاملDeformational Characteristics of Rocks Containing a Single Discontinuity (TECHNICAL NOTE)
For the purpose of exploring deformation characteristics of jointed rock masses, influence of joint inclination and confining pressure on the mechanical behavior of discontinuous rock a series of compression tests were conducted under satisfactory testing conditions on three types of sandstone from various locations. Three groups of jointed specimens were used in this research, including specim...
متن کاملAn Effective Attack-Resilient Kalman Filter-Based Approach for Dynamic State Estimation of Synchronous Machine
Kalman filtering has been widely considered for dynamic state estimation in smart grids. Despite its unique merits, the Kalman Filter (KF)-based dynamic state estimation can be undesirably influenced by cyber adversarial attacks that can potentially be launched against the communication links in the Cyber-Physical System (CPS). To enhance the security of KF-based state estimation, in this paper...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -