Inclusion of tube current control in xy-plane for cardiovascular computed tomography reduces radiation exposure and produces better images
نویسندگان
چکیده
Method Patients referred for CT angiography were randomly allocated to undergo scanning with a 320-row-detector CT using the traditional software and the newer software. Only those with no history of coronary revascularization; and no significant stenosis at the left main artery and proximal of left anterior descending artery were included for the study. The magnitude of X-ray radiation exposure with the use of the traditional software was manually determined by radiographers according to protocol, while that for the use of the new software was automatically calculated to achieve a pre-set image quality. Estimated effective radiation dose was then calculated from the extended dose length product. Two radiologists, blinded to the scanning parameters, assessed the overall image quality using a 5-point grading scale based on the quantity of mottle noise and streak artifacts. Results From September 2009 to December 2011, 156 consecutive patients were recruited. Sixty-one patients underwent scanning using the traditional software while 95 patients had scanning with the newer software. Both groups were similar in baseline characteristics. The use of the traditional software resulted in 55% more radiation exposure (mean radiation dose in mSv, traditional software: 3.1 ± 3.0; newer software: 2.0 ± 0.9). CVCT images produced with the use of the newer software were of better image quality (mean grade of image quality, traditional software: 2.6 ± 1.0; newer software: 3.8 ± 0.3).
منابع مشابه
Estimation of Absorbed and Effective Doses in Organs through Computed Tomography Examinations Using Automatic Exposure Control and Fixed Tube Current Techniques: A Phantom Case Study
Introduction: The study aimed to assess absorbed and effective doses in organs through computed tomography (CT) examinations using automatic exposure control (AEC) and fixed tube current (FTC) techniques. Material and Methods: Scanning parameters were obtained for routine adult CT examinations and used to estimate the organ absorbed and effec...
متن کاملImage Optimization and reduction of radiation dose in CT of the paranasal sinuses
Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...
متن کاملAssessment of radiation-induced cancer risk to patients undergoing computed tomography angiography scans
Background: Computed tomography angiography (CTA) scan is a suitable imaging technique to evaluate the blood vessels. However, one major disadvantage is the potential risk of cancer related to ionizing radiation exposure during the procedures. The aim of this investigation was to estimate the risk of exposure induced cancer death (REID) values for some common computed tomography angiography (CT...
متن کاملAssessment the effect of CT localizer parameter on radiation dose and image quality of GE CT spiral images, A phantom study
Introduction: Using computed tomography (CT) is increasing significantly in Iran and worldwide. Reduction of CT's radiation dose is a critical concern. The aim of this study was evaluating the effect of localizer kVp on spiral CT images when the tube current modulation (TCM) is activated. Materials and Methods: A special wedding cake phantom with circular in...
متن کاملDesign of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies
Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015