A Performance comparison of vapour compression refrigeration system using various alternative refrigerants

نویسندگان

  • A. Baskaran
  • P. Koshy Mathews
چکیده

A performance analysis on a vapour compression refrigeration system with various refrigerants mixture of R152a, RE170, R600a, and R290 were done for various mixture ratios and their results were compared with R134a as possible alternative replacement. The results showed that all of the alternative refrigerants investigated in the analysis except R431A, [R 152a (29%), R290 (71%)] have a slightly higher performance coefficient (COP) than R134a for the condensation temperature of 50 0 C and evaporating temperatures ranging between -30 0 C and 10 0 C.Refrigerant blend of R152a/RE170 (20/80 by wt%) instead of R134a was found to be a replacement refrigerant among other alternatives. The effects of the main parameters of performance analysis such as refrigerant type, degree of sub cooling and super heating on the refrigerating effect, coefficient of performance and volumetric refrigeration capacity were also investigated for various evaporating temperatures. Index Terms — Refrigeration, Alternative Refrigerants, R152a, Di methylether, Propane, Isobutane, R134a ——————————  ——————————

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

A performance analysis on a vapour compression refrigeration system with various eco-friendly refrigerants of HFC152a, HFC32, HC290, HC1270, HC600a and RE170 were done and their results were compared with R134a as possible alternative replacement. The results showed that the alternative refrigerants investigated in the analysis RE170, R152a and R600a have a slightly higher performance coefficie...

متن کامل

Methods for Improving Thermodynamic Performance of Vapour Compression Refrigeration System Using Twelve Eco Friendly Refrigerants in Primary Circuit And Nanofluid (Water- Nano Particles Based) in Secondary Circuit

This paper describes thermal modeling of Vapor Compression Refrigeration System using R134a in primary circuit and AL2O3-Water based nanofluids in secondary circuit. The model uses information of the secondary fluids input conditions geometric characteristics of the system, size of nanoparticles and the compressor speed to predict the secondary fluids output temperatures, the operating pressure...

متن کامل

Methods for Improving Exergetic Efficiency of Multi-evaporators Single Compressor and Single Expansion Valve in Vapour Compression Refrigeration Systems Using Thirteen Ecofriendly Refrigerants for Reducing Global Warming and Ozone Depletion

The methods for improving second law efficiency have been considered in this paper by using liquid vapour heat exchanger is investigated in this paper. Detailed energy and exergy analysis of multi-evaporators at different temperatures with single compressor and single expansion valve using liquid vapour heat exchanger vapour compression refrigeration systems have been done in terms of performan...

متن کامل

Thermal analysis of vapour compression refrigeration system with R152a and its blends R429A, R430A, R431A and R435A

This paper presents the analysis results of R429A, R430A, R431A and R435A as drop in substitute for R152a at various evaporating temperature with condenser temperature 30°C, 40°C and 50°C. A theoretical study of thermodynamic properties such as pressure, density, and specific volume, latent heat of vaporization compression index, and critical values are done. The theoretical performance of vapo...

متن کامل

Theoretical Exergy Analysis of HFO-1234yf and HFO-1234ze as an Alternative Replacement of HFC-134a in Simple Vapour Compression Refrigeration System

An Exergy method for theoretical analysis of a traditional vapour-compression refrigeration system equipped with liquid vapour heat exchanger (lvhe) for HFO-1234yf (2, 3, 3, 3-Tetrafluoropropene) and HFO-1234ze (trans-1, 3, 3, 3-tetrafluoroprop-1-ene), both ultra low Global Warming Potential(GWP) and zero Ozone Depletion Potential(ODP) refrigerants and comparison of the results with HFC-134a re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012