High-resolution, contrast-enhanced magnetic resonance angiography with elliptical centric k-space ordering of supra-aortic arteries compared with selective X-ray angiography.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The objective of this study was to evaluate the relative value of high-resolution, contrast-enhanced MR angiography (CE MRA) with elliptical centric k-space ordering compared with intra-arterial x-ray angiography for imaging carotid stenosis. METHODS Thirty patients with suspected stenosis of the carotid arteries were examined with CE MRA (1.5-T scanner) and x-ray angiography (aortic arch survey and selective imaging of both common carotid arteries). For the first time, not only the extracranial carotid bifurcation but all the vessel segments from the aortic arch to the circle of Willis were assessed by independent investigators. RESULTS For the internal carotid artery in the region of the extracranial carotid bifurcation, there was a very close correlation between CE MRA and x-ray angiography (sensitivity, 100%; specificity, 92%). The initially suspected overestimation of stenosis on CE MRA in 3 cases was ultimately revealed to be an underestimation on x-ray angiography. CE MRA showed slightly poorer imaging of the basal vessel segments at the level of the aortic arch (because of breathing artifacts) and the intracranial vessel segments (because of small vessel caliber and venous superimposition due to delayed sequence starts). CONCLUSIONS The MRA technique described here provides reliable results in the diagnosis of carotid stenosis and is thus suitable for replacing the invasive conventional x-ray angiography method in most cases. Further technical developments with regard to spatial resolution are still required for improved visualization of small vessels (terminal carotid branches and intracranial vessels).
منابع مشابه
Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: a prospective, intra-individual comparative analysis with digital subtraction angiography.
BACKGROUND AND PURPOSE Concomitant disease of the supra-aortic arteries can influence the outcome of surgical treatment of carotid artery stenosis. However, sensitivity and specificity data of noninvasive contrast-enhanced 3-dimensional (3D) magnetic resonance angiography (CE MRA) for the detection of steno-occlusive disease of the entire supra-aortic arteries including the circle of Willis rem...
متن کاملImproved venous suppression on renal MR angiography with recessed elliptical centric ordering of K-space.
PURPOSE To evaluate recessed elliptical centric ordering of k-space in renal magnetic resonance (MR) angiography. METHODS All imaging was performed on the same 1.5 T MR imaging system (GE Signa CVi) using the body coil for signal transmission and a phased array coil for reception. Gd, 30 ml, was injected manually at 2 ml/sec timed with automatic triggering (SmartPrep). In thirty patients usin...
متن کامل3.0T contrast-enhanced, submilimeter MRA of the supraaortic arteries: does the signal gain at high field strength allow to replace the phased array coil by the quadrature body coil?
Purpose of the study was to evaluate contrast-enhanced MR angiography (CE MRA) of the supraaortic arteries at 3.0T using the quadrature body coil as transmitter and receiver. CE MRA was performed with randomly segmented central k-space ordering (CENTRA) in 43 patients and 5 volunteers using a large FOV (350 mm) and a high image matrix of 432 x 432 (nonzerofilled voxel: 0.66 mm3).Our experience ...
متن کاملTheoretical limits of spatial resolution in elliptical-centric contrast-enhanced 3D-MRA.
The point spread function (PSF) for contrast-enhanced three-dimensional (3D) MR angiography using the elliptical centric view order is derived. This view order has been shown previously to provide high venous suppression thereby enabling long acquisition times capable of high spatial resolution. The dependence of the PSF on TR, field of view (FOV), scan time, and trigger time are shown explicit...
متن کاملFeathering: Vertebral artery pseudostenosis with elliptical centric contrast-enhanced MR angiography.
Elliptical centric contrast-enhanced MR angiography of the cervical vasculature is a well-established technique that in many practices has replaced conventional angiography for several clinical indications, including atherosclerotic disease and dissections. Occasionally blurring or loss of signal intensity occurs in the vertebral arteries, especially in young patients with rapid circulation tim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 33 6 شماره
صفحات -
تاریخ انتشار 2002