The measurement of lung water
نویسندگان
چکیده
INTRODUCTION: In this review, we compare the spectrum of currently available methods for quantifying pulmonary edema in patients. REVIEW: Imaging and indicator dilution techniques comprise the most common strategies for measuring lung water at the bedside. The most accurate (within 10% of the gravimetric gold standard) and most reproducible (< 5% between-test variation) are also, unfortunately, the most expensive and most difficult to implement for purposes of large-scale clinical trials or for routine clinical practice. CONCLUSION: The standard chest radiograph remains the best screening test for the detection of pulmonary edema. Indicator-dilution techniques are probably the best available method at present for quantitation in patient groups.
منابع مشابه
Calculation of absorbed dose in lung tissue equivalent and compared it with prediction of a treatment planning system using Collapsed Cone Convolution algorithm
External radiotherapy is used for treatment of various types of cancers. Due to the impossibility of measuring the absorbed dose delivered to different organs during irradiation, treatment planning systems (TPSs) have been utilized for calculation of absorbed dose before a radiotherapy procedure. Thus, the accuracy and precession of the TPS is essential.The aim of this study is investigation of...
متن کاملExposure assessment of the radon in residential tap water in Kastamonu
Background: It is considered that if radon gas is inhaled and ingested, it is the primary health risks for lung and stomach cancers. This paper presents the measurement results of radon activity concentrations both residential tap water and dam water for Kastamonu city Centre-Turkey. Materials and Methods: The radon activity concentrations of water samples collected from 60 tap waters at four l...
متن کاملDose calculations accuracy of TiGRT treatment planning system for small IMRT beamlets in heterogeneous lung phantom
Background: Accurate dose calculations in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS). In the current study, the dose calculation accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calculations. Materials and Methods: The head of Siemens Oncor-impression linac...
متن کاملModification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds
Background:Â A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective:Â The present study aims to modify source strength for different configurations of 125I and 103...
متن کاملDETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
متن کاملThe measurement of droplet size distribution of water-oil emulsion through NMR method
The effects of water/oil volume ratio, type and concentration of demulsifier, water salinity and mixing speed on the average water droplets size in water-oil emulsion are evaluated at different times through NMR measurements.The type and concentration of demulsifier have the greatest effects on the average droplet size with 38% and 31.5%, respectively. The water/oil volume ratio, water salinity...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Critical Care
دوره 3 شماره
صفحات -
تاریخ انتشار 1999