Use of a Computed Tomography Based Approach to Validate Noninvasive Devices to Measure Rotational Knee Laxity
نویسندگان
چکیده
The purpose of this study is to validate a noninvasive rotational knee laxity measuring device called "Rotameter P2" with an approach based on Computed Tomography (CT). This CT-approach using X-rays is hence invasive and can be regarded as a precise reference method that may also be applied to similar devices. An error due to imperfect femur fixation was observed but can be neglected for small torques. The most significant estimation error is due to the unavoidable soft tissues rotation and hence flexibility in the measurement chain. The error increases with the applied torque. The assessment showed that the rotational knee angle measured with the Rotameter is still overestimated because of thigh and femur displacement, soft tissues deformation, and measurement artefacts adding up to a maximum of 285% error at +15 Nm for the Internal Rotation of female volunteers. This may be questioned if such noninvasive devices for measuring the Tibia-Femoral Rotation (TFR) can help diagnosing knee pathologies and investigate ligament reconstructive surgery.
منابع مشابه
Design, Repeatability, and Comparison to Literature Data of a New Noninvasive Device Called “Rotameter” to Measure Rotational Knee Laxity
The present paper deals with the design, the repeatability, and the comparison to literature data of a new measuring device called "Rotameter" to characterize the rotational knee laxity or the tibia-femoral rotation (TFR). The initial prototype P1 of the Rotameter is shortly introduced and then modified according to trials carried out on a prosthetic leg and on five healthy volunteers, leading ...
متن کاملThe rotational alignment of the lower limbs in recurrent dislocation of the patella.
The rotational alignment tヲfthe lovver limbs of 24 patients who developed r巴currentdislocation of the patella were measured by means of computed axial tomography. The femoral anteversion and the external rotation of the knee joint of these patients respectively showed 31.9土15.2° and 9.2土6.8° on the average. These figures were significantly larger than those of the control. The average external ...
متن کاملComputed Tomographic measurement of distal femor rotation in Iranian population
Background: Proper rotation of components in total knee arthroplasty (TKA) will largely affect the postoperative outcome. Ethnical variation may affect rotational profile. We aimed to evaluate distal femur rotation in Iranian population using transepicondylar axes. Methods : From a total of 450 knee CT scans and via consecutive sampling, 150 qualified subjects with normal lower extremities ...
متن کاملHuman knee laxity in ACL-deficient and physiological contralateral joints: intra-operative measurements using a navigation system
BACKGROUND The comprehension of human knee laxity and of the failures of relevant surgical reconstructions of the anterior cruciate ligament (ACL) can be enhanced by the knowledge of the laximetric status of the contralateral healthy knee (CHK). Rarely this is available in patients, directly from the skeletal structures, and for a number of the standard clinical tests. The general aim of this s...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015