A polymeric sealant inhibits anastomotic suture hole bleeding more rapidly than gelfoam/thrombin: results of a randomized controlled trial.

نویسندگان

  • Marc Glickman
  • Ali Gheissari
  • Samuel Money
  • John Martin
  • Jeffrey L Ballard
چکیده

HYPOTHESIS An experimental polymeric sealant (CoSeal [Cohesion Technologies, Palo Alto, Calif]) provides equivalent anastomotic sealing to Gelfoam (Upjohn, Kalamazoo, Mich)/thrombin during surgical placement of prosthetic vascular grafts. DESIGN Randomized controlled trial. SETTING Nine university-affiliated medical centers. PATIENTS One hundred forty-eight patients scheduled for implantation of polytetrafluoroethylene grafts, mainly for infrainguinal revascularization procedures or the creation of dialysis access shunts, who were treated randomly with either an experimental intervention (n = 74) or control (n = 74). INTERVENTION Following polytetrafluoroethylene graft placement, anastomotic suture hole bleeding was treated intraoperatively in all control subjects with Gelfoam/thrombin. Subjects in the experimental group had the polymeric sealant applied directly to the suture lines without concomitant manual compression. MAIN OUTCOME MEASURES Primary treatment success was defined as the proportion of subjects in each group that achieved complete anastomotic sealing within 10 minutes. The proportion of subjects that achieved immediate sealing and the time required to fully inhibit suture hole bleeding also were compared between treatment groups. RESULTS Overall 10-minute sealing success was equivalent (86% vs 80%; P =.29) between experimental and control subjects, respectively. However, subjects treated with CoSeal achieved immediate anastomotic sealing at more than twice the rate of subjects treated with Gelfoam/thrombin (47% vs 20%; P<.001). Consequently, the median time needed to inhibit bleeding in control subjects was more than 10 times longer than for experimental subjects (16.5 seconds vs 189.0 seconds; P =.01). Strikingly similar findings for all comparisons were observed separately for subgroups of subjects having infrainguinal bypass grafting and for those undergoing placement of dialysis access shunts. CONCLUSIONS The experimental sealant offers equivalent anastomotic sealing performance compared with Gelfoam/thrombin, but it provides this desired effect in a significantly more rapid time frame.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results from a First-in-Human Trial of a Novel Vascular Sealant

BACKGROUND Suture hole bleeding from synthetic grafts presents a hemostatic challenge. The designs of many vascular sealants are not optimal (non-adherence to wet surfaces, excessive swelling, inflexible). PreveLeak™ (formerly ArterX ((®)) ) is a polyaldehyde-bovine serum albumin-based sealant whose efficacy, safety, and performance were evaluated in this first-in-human study. MATERIALS AND M...

متن کامل

Assessment of the effect on blood loss and transfusion requirements when adding a polyethylene glycol sealant to the anastomotic closure of aortic procedures: a case–control analysis of 102 patients undergoing Bentall procedures

BACKGROUND The use of CoSeal(®), a polyethylene glycol sealant, in cardiac and vascular surgery for prevention of anastomotic bleeding has been subject to prior investigations. We analysed our perioperative data to determine the clinical benefit of using polyethylene glycol sealant to inhibit suture line bleeding in aortic surgery. METHODS From January 2004 to June 2006, 124 patients underwen...

متن کامل

Quantitation and control of pulpal bleeding.

The purpose of this investigation was to use a quantitative technique to evaluate the hemostatic properties of gelfoam and thrombin. To accomplish this, blood was drawn from dogs, labeled in vitro with 5tCr and then reinjected back into the donor dogs. When pulp exposures were made, all blood shed from the site was collected in 30 second intervals to allow calculation of the rate of bleeding. T...

متن کامل

"How I do it: utilization of high-pressure sealants in aortic reconstruction"

BACKGROUND Suture-line hemostasis, reinforcement of friable tissue, and adhesion prevention are key concerns for patients undergoing cardiac surgery for aortic reconstruction. Failure to secure hemostasis at anastomotic junctures and reinforce fragile tissue may lead to increased blood loss, additional blood product requirements, increased operative time, and, in extreme cases, reoperation. Pat...

متن کامل

A Comparison of Avitene Ultrafoam versus Gelfoam With and Without Thrombin to Effectively Control Bleeding

Topical hemostatic agents are used to stop bleeding in a wide range of surgical procedures. Many of the products currently available are not effective in controlling blood loss as quickly as desired, therefore, it has become common to soak hemostatic agents with thrombin, the enzyme that catalyzes the conversion of fibrinogen to fibrin. The preparation of thrombin requires additional preparatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of surgery

دوره 137 3  شماره 

صفحات  -

تاریخ انتشار 2002