Pre-heating of components in cemented total hip arthroplasty.
نویسندگان
چکیده
Fatigue fractures which originate at stress-concentrating voids located at the implant-cement interface are a potential cause of septic loosening of cemented femoral components. Heating of the component to 44 degrees C is known to reduce the porosity of the cement-prosthesis interface. The temperature of the cement-bone interface was recorded intra-operatively as 32.3 degrees C. A simulated femoral model was devised to study the effect of heating of the component on the implant-cement interface. Heating of the implant and vacuum mixing have a synergistic effect on the porosity of the implant-cement interface, and heating also reverses the gradients of microhardness in the mantle. Heating of the implant also reduces porosity at the interface depending on the temperature. A minimum difference in temperature between the implant and the bone of 3 degrees C was required to produce this effect. The optimal difference was 7 degrees C, representing a balance between maximal reduction of porosity and an increased risk of thermal injury. Using contemporary cementing techniques, heating the implant to 40 degrees C is recommended to produce an optimum effect.
منابع مشابه
Effects of pre-cooling and pre-heating procedures on cement polymerization and thermal osteonecrosis in cemented hip replacements.
Numerical studies were performed to investigate bone cement polymerization, temperature history and thermal osteonecrosis in cemented hip replacements with finite element methods. In this paper, the effects of pre-cooling and pre-heating of the prosthesis and/or the cement prior to implantation were simulated. It was found that the cement polymerization initiated near the bone-cement interface ...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملThe relative cost of cemented and uncemented total hip arthroplasties.
The use of uncemented femoral stems in primary total hip arthroplasty (THA) has been slow to develop in the UK because of the lack of encouraging published long-term follow-up data, the continued success of the cemented primary THA, and the perceived excessive relative cost of the uncemented THA. In this article, we argue that the total costs of 3 "proven" uncemented stems are comparable with c...
متن کاملAcetabular components in total hip arthroplasty: is there evidence that cementless fixation is better?
BACKGROUND The use of cementless acetabular components in total hip arthroplasty has gained popularity over the past decade. Most total hip arthroplasties being performed in North America currently use cementless acetabular components. The objective of this systematic review and meta-analysis was to compare the survivorship and revision rate of cemented and cementless acetabular components util...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 86 8 شماره
صفحات -
تاریخ انتشار 2004