Stepwise calibration of focused plenoptic cameras
نویسندگان
چکیده
Monocular plenoptic cameras are slightly modified, off-the-shelf cameras that have novel capabilities as they allow for truly passive, high-resolution range sensing through a single camera lens. Commercial plenoptic cameras, however, are presently delivering range data in non-metric units, which is a barrier to novel applications e.g. in the realm of robotics. In this work we revisit the calibration of focused plenoptic cameras and bring forward a novel approach that leverages traditional methods for camera calibration in order to deskill the calibration procedure and to increase accuracy. First, we detach the estimation of parameters related to either brightness images or depth data. Second, we present novel initialization methods for the parameters of the thin lens camera model—the only information required for calibration is now the size of the pixel element and the geometry of the calibration plate. The accuracy of the calibration results corroborates our belief that monocular plenoptic imaging is a disruptive technology that is capable of conquering new markets as well as traditional imaging domains.
منابع مشابه
Calibration and Accuracy Analysis of a Focused Plenoptic Camera
In this article we introduce new methods for the calibration of depth images from focused plenoptic cameras and validate the results. We start with a brief description of the concept of a focused plenoptic camera and how from the recorded raw image a depth map can be estimated. For this camera, an analytical expression of the depth accuracy is derived for the first time. In the main part of the...
متن کاملMetric Calibration of a Focused Plenoptic Camera Based on a 3d Calibration Target
In this paper we present a new calibration approach for focused plenoptic cameras. We derive a new mathematical projection model of a focused plenoptic camera which considers lateral as well as depth distortion. Therefore, we derive a new depth distortion model directly from the theory of depth estimation in a focused plenoptic camera. In total the model consists of five intrinsic parameters, t...
متن کاملUnconstrained Two-parallel-plane Model for Focused Plenoptic Cameras Calibration
The plenoptic camera can capture both angular and spatial information of the rays, enabling 3D reconstruction by single exposure. The geometry of the recovered scene structure is affected by the calibration of the plenoptic camera significantly. In this paper, we propose a novel unconstrained two-parallel-plane (TPP) model with 7 parameters to describe a 4D light field. By reconstructing scene ...
متن کاملOn the Calibration of Focused Plenoptic Cameras
Plenoptic cameras provide a robust way to capture 3D information with a single shot. This is accomplished by encoding the direction of the incoming rays with a microlens array (MLA) in front of the camera sensor. In the focused plenoptic camera, a MLA acts like multiple small cameras that capture the virtual scene on the focus plane of a main lens from slightly different angles, which enables a...
متن کاملCalibration of Plenoptic 2.0 Cameras and use in 3DPTV Investigations
Plenoptic 1.0 cameras have already been investigated as a means for performing 3DPIV. Plenoptic 2.0 cameras have an enhanced in-plane resolution, but are limited to less dense particle fields by their depth-detection method, and are thus less appropriate for 3DPIV. A technique more suited to less dense particle fields is 3DPTV. Time-resolved 3DPTV will be possible due to the high frame rate ava...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computer Vision and Image Understanding
دوره 145 شماره
صفحات -
تاریخ انتشار 2016