Clinical Guidelines for the Manual Titration of Positive Airway Pressure in Patients with Obstructive Sleep Apnea Positive Airway Pressure Titration Task Force of the American Academy of Sleep Medicine

نویسندگان

  • Alejandro Chediak
  • B. Berry
  • Lee K. Brown
  • David Gozal
  • Conrad Iber
  • Sairam Parthasarathy
  • Stuart F. Quan
  • James A. Rowley
چکیده

157 Summary: Positive airway pressure (PAP) devices are used to treat patients with sleep related breathing disorders (SRBDs), including obstructive sleep apnea (OSA). After a patient is diagnosed with OSA, the current standard of practice involves performing attended polysomnography (PSG), during which positive airway pressure is adjusted throughout the recording period to determine the optimal pressure for maintaining upper airway patency. Continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BPAP) represent the two forms of PAP that are manually titrated during PSG to determine the single fixed pressure of CPAP or the fixed inspiratory and expiratory positive airway pressures (IPAP and EPAP, respectively) of BPAP for subsequent nightly usage. A PAP Titration Task Force of the American Academy of Sleep Medicine reviewed the available literature. Based on this review, the Task Force developed these recommendations for conducting CPAP and BPAP titrations. Major recommendations are as follows: (1) All potential PAP titration candidates should receive adequate PAP education, hands-on demonstration, careful mask fitting, and acclimatization prior to titration. (2) CPAP (IPAP and/or EPAP for patients on BPAP) should be increased until the following obstructive respiratory events are eliminated (no specific order) or the recommended maximum CPAP (IPAP for patients on BPAP) is reached: apneas, hypopneas, respiratory effort-related arousals (RERAs), and snoring. (3) The recommended minimum starting CPAP should be 4 cm H2O for pediatric and adult patients, and the recommended minimum starting IPAP and EPAP should be 8 cm H2O and 4 cm H2O, respectively, for pediatric and adult patients on Clinical Guidelines for the Manual Titration of Positive Airway Pressure in Patients with Obstructive Sleep Apnea

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of auto-titrating continuous positive airway pressure for treatment of adult obstructive sleep apnea. An American Academy of Sleep Medicine review.

This paper reviews the efficacy of auto-titrating continuous positive airway pressure (APAP) for treatment of obstructive sleep apnea. It is based on a review of 30 articles published in peer review journals conducted by a task force appointed by the American Academy of Sleep Medicine to develop practice parameters for use of APAP devices for treatment of obstructive sleep apnea (OSA). The data...

متن کامل

Concerns regarding the pediatric component of the AASM clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea.

Positive airway pressure (PAP) devices are used to treat patients with sleep related breathing disorders (SRBDs), including obstructive sleep apnea (OSA). After a patient is diagnosed with OSA, the current standard of practice involves performing attended polysomnography (PSG), during which positive airway pressure is adjusted throughout the recording period to determine the optimal pressure fo...

متن کامل

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

Can patients with obstructive sleep apnea titrate their own continuous positive airway pressure?

Manual continuous positive airway pressure (CPAP) titration in a sleep laboratory is costly and limits access for diagnostic studies. Many factors affect CPAP compliance, but education and support, rather than in-laboratory CPAP titration, appear to be pivotal. Self-adjustment of CPAP at home will provide equal or superior efficacy in the treatment of obstructive sleep apnea (OSA) as compared w...

متن کامل

Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report.

These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008