Variation in Optimal Sagittal Alignment of the Femoral Component in Total Knee Arthroplasty.
نویسندگان
چکیده
Accurate sagittal alignment of the femoral component in total knee arthroplasty is crucial for prosthesis longevity, improved function, and patient satisfaction. However, there is variation in the techniques used to attain optimal sagittal femoral component placement in total knee arthroplasty. Femoral component flexion in imageless navigation is based on the mechanical axis rather than the distal femoral anatomy, and there is significant variability in the anatomy of the distal femur. The purpose of this study was to accurately determine the mean distal femoral flexion angle of a representative population and whether variability of the distal femoral flexion angle correlates with race, femur length, or radius of curvature. The mean degree of distal femoral flexion was determined by assessing distal femoral anatomy on computed tomography scans of paired femurs of 1235 patients without evidence of previous fracture, deformity, or surgical implants. The mean±SD distal femoral flexion angle was 2.90°±1.52°, with 80.2% of knees within 3°±2°. Therefore, placing the component in 3° of flexion from the mechanical axis would attain a satisfactory position in most cases. However, further analysis of the patient data revealed 11.4% of Asians, 7.3% of African Americans, and 8.3% of whites had a distal femoral flexion angle greater than 5°. Additionally, the data revealed a moderately strong negative correlation between the distal femoral flexion and the overall radius of curvature of the femur. This preliminary study highlights the need for improved methods for selecting femoral component position in the sagittal plane when using navigation for total knee arthroplasty. [Orthopedics. 2017; 40(2):102-106.].
منابع مشابه
The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملComparison of an Accelerometer-Based Portable Navigation System, Patient-Specific Instrumentation, and Conventional Instrumentation for Femoral Alignment in Total Knee Arthroplasty
Purpose The KneeAlign2 (KA2, OrthoAlign Inc.) accelerometer-based portable navigation system and patient-specific instrumentation (PSI; Signature, ZimmerBiomet) are widely used for ideal femoral component alignment in total knee arthroplasty (TKA). However, there has been no comparative study of the KA2 system, PSI, and conventional intramedullary instrumentation (CON). The purpose of this stud...
متن کاملWhat is the optimal alignment of the tibial and femoral components in knee arthroplasty?
BACKGROUND Surgeon-dependent factors such as optimal implant alignment are thought to play a significant role in outcome following primary total knee arthroplasty (TKA). Exact definitions and references for optimal alignment are, however, still being debated. This overview of the literature describes different definitions of component alignment following primary TKA for (1) tibiofemoral alignme...
متن کاملThe Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty.
In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment of the femoral component in total knee arthroplasty (TKA). There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittal femoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cortical line (DACL) ...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopedics
دوره 40 2 شماره
صفحات -
تاریخ انتشار 2017