Imaging artifacts of medical instruments in ultrasound-guided interventions.
نویسندگان
چکیده
OBJECTIVE Real-time 3-dimensional (3D) ultrasound imaging has the potential to become a dominant imaging technique for minimally invasive surgery. One barrier to its widespread use is that surgical instruments generate imaging artifacts, which can obfuscate their location, orientation, and geometry and obscure nearby tissue. The purpose of this study was to identify and describe the types of artifacts which could be produced by metallic instruments during interventions guided by 3D ultrasound imaging. METHODS Three imaging studies were performed. First, imaging artifacts from stainless steel rods were identified in vitro and acoustically characterized. Second, 3 typical minimally invasive instruments were imaged (in vitro and in vivo), and their artifacts were analyzed. The third study compared the intensity of imaging artifacts (in vitro and in vivo) from stainless steel rods with rods composed of 3 different materials and stainless steel rods with roughened and coated surfaces. RESULTS For the stainless steel rods, all observed artifacts are described and illustrated, and their physical origins are explained. Artifacts from the 3 minimally invasive instruments are characterized with the use of the artifacts observed with the rods. Finally, it is shown that artifacts can be greatly reduced through the use of alternate materials or by surface modification. CONCLUSIONS Instrument artifacts in 3D ultrasound images can be more confusing than those from the same instruments imaged in 2 dimensions. Real-time 3D ultrasound imaging can, however, be used effectively for in vivo imaging of minimally invasive instruments by using artifact mitigation techniques, including careful selection of probe and incision locations, as well as by instrument modification.
منابع مشابه
Passive Markers for Ultrasound Tracking of Surgical Instruments
A family of passive markers is presented by which the position and orientation of a surgical instrument can be computed from its ultrasound image using simple image processing. These markers address the problem of imaging instruments and tissue simultaneously in ultrasound-guided interventions. Marker-based estimates of instrument location can be used in augmented reality displays or for image-...
متن کامل3D and 4D ultrasonography – review of doubts and controversies
A constant progress in sonographic techniques and rapid evolution of 3D/4D techniques gave us a lot of advantages but made us also to ask and answer many important questions. We review and discuss such important topics like: marketing pressure, safety and law regulations, validity of 3D/4D US diagnostic and its impact on clinical route, 3D/4D and prenatal bonding/maternal anxiety, learning proc...
متن کاملLaparoscopic Assisted ultrasound guided Percutaneous Nephrolithotomy (PCNL) in Ectopic Pelvic Kidney
We report a patient with pain, abdominal palpable mass and a history of previous open renal stone surgery. Imaging studies showed a right pelvic kidney with multiple calyceal stones. We describe the successful management through laparoscopic assisted percutaneous nephrolithotomy with ultrasonography (PCNL) in ectopic pelvic kidney, stressing that this method is a minimally invasive therapeutic...
متن کاملPET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملA comparison of ultrasound guided corticosteroid injection vs ozone injection in grade 3 knee osteoarthritis
Background: Osteoarthritis (OA) is a degenerative disease that can cause pain and limited function. One of the non-surgical treatments is intra-articular ozone injection. This study aimed to compare the effect of ultrasound-guided corticosteroid injection with ozone injection in patients with grade 3 osteoarthritis of the knee. Methods: This randomized, double-blind, clinical trial was carried...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
دوره 26 10 شماره
صفحات -
تاریخ انتشار 2007