Rapid Diagnosis of Tuberculosis with the Xpert MTB/RIF Assay in High Burden Countries: A Cost-Effectiveness Analysis
نویسندگان
چکیده
BACKGROUND Xpert MTB/RIF (Xpert) is a promising new rapid diagnostic technology for tuberculosis (TB) that has characteristics that suggest large-scale roll-out. However, because the test is expensive, there are concerns among TB program managers and policy makers regarding its affordability for low- and middle-income settings. METHODS AND FINDINGS We estimate the impact of the introduction of Xpert on the costs and cost-effectiveness of TB care using decision analytic modelling, comparing the introduction of Xpert to a base case of smear microscopy and clinical diagnosis in India, South Africa, and Uganda. The introduction of Xpert increases TB case finding in all three settings; from 72%-85% to 95%-99% of the cohort of individuals with suspected TB, compared to the base case. Diagnostic costs (including the costs of testing all individuals with suspected TB) also increase: from US$28-US$49 to US$133-US$146 and US$137-US$151 per TB case detected when Xpert is used "in addition to" and "as a replacement of" smear microscopy, respectively. The incremental cost effectiveness ratios (ICERs) for using Xpert "in addition to" smear microscopy, compared to the base case, range from US$41-$110 per disability adjusted life year (DALY) averted. Likewise the ICERS for using Xpert "as a replacement of" smear microscopy range from US$52-$138 per DALY averted. These ICERs are below the World Health Organization (WHO) willingness to pay threshold. CONCLUSIONS Our results suggest that Xpert is a cost-effective method of TB diagnosis, compared to a base case of smear microscopy and clinical diagnosis of smear-negative TB in low- and middle-income settings where, with its ability to substantially increase case finding, it has important potential for improving TB diagnosis and control. The extent of cost-effectiveness gain to TB programmes from deploying Xpert is primarily dependent on current TB diagnostic practices. Further work is required during scale-up to validate these findings.
منابع مشابه
Advances in tuberculosis diagnostics: the Xpert MTB/RIF assay and future prospects for a point-of-care test.
Rapid progress has been made in the development of new diagnostic assays for tuberculosis in recent years. New technologies have been developed and assessed, and are now being implemented. The Xpert MTB/RIF assay, which enables simultaneous detection of Mycobacterium tuberculosis (MTB) and rifampicin (RIF) resistance, was endorsed by WHO in December, 2010. This assay was specifically recommende...
متن کاملRapid and Accurate Detection of Mycobacterium tuberculosis in Sputum Samples by Cepheid Xpert MTB/RIF Assay—A Clinical Validation Study
BACKGROUND A crucial impediment to global tuberculosis control is the lack of an accurate, rapid diagnostic test for detection of patients with active TB. A new, rapid diagnostic method, (Cepheid) Xpert MTB/RIF Assay, is an automated sample preparation and real-time PCR instrument, which was shown to have good potential as an alternative to current reference standard sputum microscopy and cultu...
متن کاملXpert MTB/RIF for diagnosis of tuberculosis and drug-resistant tuberculosis: a cost and affordability analysis.
Xpert MTB/RIF is a rapid test to diagnose tuberculosis (TB) and rifampicin-resistant TB. Cost and affordability will influence its uptake. We assessed the cost, globally and in 36 high-burden countries, of two strategies for diagnosing TB and multidrug-resistant (MDR)-TB: Xpert with follow-on diagnostics, and conventional diagnostics. Costs were compared with funding available for TB care and c...
متن کاملUsing Xpert MTB/RIF
Xpert MTB/RIF is an automated real-time polymerase chain reaction test for simultaneous detection of tuberculosis and rifampicin resistance. Xpert MTB/RIF has demonstrated excellent accuracy in clinical evaluation studies, but has reduced sensitivity for detection of smear-negative tuberculosis. Since sample processing and detection are largely automated, Xpert MTB/RIF is potentially suitable f...
متن کاملRapid diagnosis of tuberculosis using Xpert MTB/RIF assay - Report from a developing country
OBJECTIVE To evaluate the diagnostic accuracy of the Xpert MTB/RIF assay for the detection of M. tuberculosis in pulmonary and extrapulmonary specimens and to compare it with conventional techniques. METHODS During a period of 10 months from December 2012 through September 2013, two hundred and forty five clinically TB suspects were enrolled for Xpert MTB\RIF assay. The cohort comprised of 20...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2011