Patient-Specific MRI-Based Right Ventricle Models Using Different Zero-Load Diastole and Systole Geometries for Better Cardiac Stress and Strain Calculations and Pulmonary Valve Replacement Surgical Outcome Predictions

نویسندگان

  • Dalin Tang
  • Pedro J. del Nido
  • Chun Yang
  • Heng Zuo
  • Xueying Huang
  • Rahul H. Rathod
  • Vasu Gooty
  • Alexander Tang
  • Zheyang Wu
  • Kristen L. Billiar
  • Tal Geva
چکیده

BACKGROUND Accurate calculation of ventricular stress and strain is critical for cardiovascular investigations. Sarcomere shortening in active contraction leads to change of ventricular zero-stress configurations during the cardiac cycle. A new model using different zero-load diastole and systole geometries was introduced to provide more accurate cardiac stress/strain calculations with potential to predict post pulmonary valve replacement (PVR) surgical outcome. METHODS Cardiac magnetic resonance (CMR) data were obtained from 16 patients with repaired tetralogy of Fallot prior to and 6 months after pulmonary valve replacement (8 male, 8 female, mean age 34.5 years). Patients were divided into Group 1 (n = 8) with better post PVR outcome and Group 2 (n = 8) with worse post PVR outcome based on their change in RV ejection fraction (EF). CMR-based patient-specific computational RV/LV models using one zero-load geometry (1G model) and two zero-load geometries (diastole and systole, 2G model) were constructed and RV wall thickness, volume, circumferential and longitudinal curvatures, mechanical stress and strain were obtained for analysis. Pairwise T-test and Linear Mixed Effect (LME) model were used to determine if the differences from the 1G and 2G models were statistically significant, with the dependence of the pair-wise observations and the patient-slice clustering effects being taken into consideration. For group comparisons, continuous variables (RV volumes, WT, C- and L- curvatures, and stress and strain values) were summarized as mean ± SD and compared between the outcome groups by using an unpaired Student t-test. Logistic regression analysis was used to identify potential morphological and mechanical predictors for post PVR surgical outcome. RESULTS Based on results from the 16 patients, mean begin-ejection stress and strain from the 2G model were 28% and 40% higher than that from the 1G model, respectively. Using the 2G model results, RV EF changes correlated negatively with stress (r = -0.609, P = 0.012) and with pre-PVR RV end-diastole volume (r = -0.60, P = 0.015), but did not correlate with WT, C-curvature, L-curvature, or strain. At begin-ejection, mean RV stress of Group 2 was 57.4% higher than that of Group 1 (130.1±60.7 vs. 82.7±38.8 kPa, P = 0.0042). Stress was the only parameter that showed significant differences between the two groups. The combination of circumferential curvature, RV volume and the difference between begin-ejection stress and end-ejection stress was the best predictor for post PVR outcome with an area under the ROC curve of 0.855. The begin-ejection stress was the best single predictor among the 8 individual parameters with an area under the ROC curve of 0.782. CONCLUSION The new 2G model may be able to provide more accurate ventricular stress and strain calculations for potential clinical applications. Combining morphological and mechanical parameters may provide better predictions for post PVR outcome.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Image-based immersed boundary model of the aortic root

Each year, approximately 300,000 heart valve repair or replacement procedures are performed worldwide, including approximately 70,000 aortic valve replacement surgeries in the United States alone. Computational platforms for simulating cardiovascular devices such as prosthetic heart valves promise to improve device design and assist in treatment planning, including patient-specific device selec...

متن کامل

Asymmetric Septal Hypertrophy

This patient demonstrated abnormal echoes which were present in the pulmonic valve echocardiogram during systole, in the right ventricular outflow tract in systole and diastole, and more inferiorly in the right ventricular cavity in diastole. The tricuspid valve appeared normal. These findings suggested the presence of a tumor high in the right ventricle, which traversed the pulmonic orifice in...

متن کامل

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Cardiac MRI and pulmonary hypertension-the pressure is on!

Methods Subjects were eligible for entry if they had documented PAH as defined by WHO Criteria and were referred for a clinically indicated CMR exam where routine 3D metrics and LGE were performed. All images were retrospectively reviewed. The data collected as follows: right and left ventricular RV/LV EDVI and ESVI; RVEF and LVEF; RV anterior and inferior hinge point angle measurements (systol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016