Measuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors?

نویسندگان

  • S de Lusignan
  • K Thiru
  • K Meredith
  • A Majeed
  • P Johnson
چکیده

OBJECTIVES To compare the agreement between conventional measurement of blood pressure and measurements obtained using two automated devices; and to compare how comfortable each of the three methods of measurement were for patients. METHODS Blood pressure measurements and patient comfort scores were recorded using three different devices in 125-surgery and 40-community patients. The devices used were a conventional aneroid sphygmomanometer, an automated device that measured blood pressure on the upper arm and an automated device that measured blood pressure at the wrist. In each patient, the difference between the conventional and automatic measurement was calculated. The limits of agreement of each device were then calculated as the mean difference +/-1.96 standard deviations. RESULTS In surgery patients, the width of limits of agreement of wrist measurement were 20.0 mm Hg and 12.1 mm Hg for systolic and diastolic blood pressure respectively, compared with 26. 4 mm Hg and 27.7 mm Hg for automatic arm measurement. In community patients, the width of limits of agreement of wrist measurement were 11.6 mm Hg and 11.0 mm Hg for systolic and diastolic blood pressure respectively, compared with 19.5 mm Hg and 12.1 mm Hg for automatic arm measurement. Surgery patients also reported that wrist measurement of blood pressure was significantly more comfortable than either manual or automatic arm measurement (mean comfort scores 4.03 for automatic wrist and 2.13 for automatic arm measurement, Friedman's Test, P<0.001). CONCLUSIONS Blood pressure measurements taken using the wrist device agreed more closely with those obtained using a conventional aneroid sphygmomanometer than the arm device. The wrist device was also more comfortable for patients than two other methods of blood pressure measurement. Public Health (2000) 114, 165-168

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oscillometric wrist blood pressure measuring devices.

Devices measuring blood pressure oscillometrically at the wrist are becoming more and more popular. These devices are small, easy to handle and can measure blood pressure without the need to undress. However, few of the wrist devices have been validated properly, i.e. according to internationally accepted protocols. In this article current literature on wrist blood pressure measuring devices is...

متن کامل

مقایسه فشار خون بیماران همودیالیزی در دو وضعیت خوابیده به پشت و نیمه نشسته

  ABSTRACT   Background and Aim: Hemodialysis is the most common method of treatment for chronic renal insufficiency an advanced and unretrieveable disorder. Hemodialysis has some complications on which the position of the patient can be effective. Routinely, patients are placed on supine position during hemodialysis, but they are not comfortable in this position, and most of them would like to...

متن کامل

A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.

BACKGROUND In morbidly obese patients, oscillometric blood pressure measurements with an upper-arm cuff are often difficult to perform. The alternative method, invasive blood pressure monitoring, can be difficult to place and is associated with risks. A wrist-mounted blood pressure-monitoring device, the Vasotrac, provides accurate blood pressure measurements in lean patients. Even in the obese...

متن کامل

تأثیر وضعیت‌های مختلف قرارگیری اندام‌های بیماران مبتلا به پرفشاری خون بر میزان فشارخون آنان

Introduction: In hypertensive patients M position (sitting, right arm at the level of heart and both plantar surface of foots on the floor) is the standard position for measurment of blood pressure since it reveals the “true” pressure. Materials and Methods: It is a quaziexperimental study that compares effect of different positions of limbs on blood pressure of hypertensive patients. The sampl...

متن کامل

Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010

BACKGROUND Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Public health

دوره 114 3  شماره 

صفحات  -

تاریخ انتشار 2000