Influence of high frequency ventilation at different end-expiratory lung volumes on the development of lung damage during lung lavage in rabbits.
نویسندگان
چکیده
The effects of high frequency ventilation in combination with sustained inflations was studied in the surfactant-deficient lungs of 18 New Zealand White rabbits (weight 1.9-2.1 kg) during anaesthesia with urethane and neuromuscular block with pancuronium. Lung damage was induced by repeated lung lavage. In nine rabbits (group I) baseline ventilator settings were maintained constant throughout the study and airway pressure was readjusted to achieve a constant tidal volume. In the other nine rabbits (group II), ventilation was reinstituted after lung lavage with one period of four sustained inflations followed immediately by high frequency ventilation. In group I there was a significant decrease in gas exchange for oxygen and deterioration in pulmonary mechanics, whereas in group II there was little change in baseline blood-gas values or pulmonary mechanics. These data suggest that, with adequate ventilatory management during the period of lung lavage, the lung damage produced by this manoeuvre may be obviated.
منابع مشابه
Comparison of static end-expiratory and effective lung volumes for gas exchange in healthy and surfactant-depleted lungs.
BACKGROUND Effective lung volume (ELV) for gas exchange is a new measure that could be used as a real-time guide during controlled mechanical ventilation. The authors established the relationships of ELV to static end-expiratory lung volume (EELV) with varying levels of positive end-expiratory pressure (PEEP) in healthy and surfactant-depleted rabbit lungs. METHODS Nine rabbits were anestheti...
متن کاملComparisons of different mean airway pressure settings during high-frequency oscillation in inflammatory response to oleic acid-induced lung injury in rabbits
PURPOSE The present study was designed to examine effects of different mean airway pressure (MAP) settings during high-frequency oscillation (HFO) on oxygenation and inflammatory responses to acute lung injury (ALI) in rabbits. METHODS Anesthetized rabbits were mechanically ventilated with a conventional mechanical ventilation (CMV) mode (tidal volume 6 ml/kg, inspired oxygen fraction [F(Io2)...
متن کاملThe effect of positive-end expiratory pressure on oxygenation during high frequency jet ventilation and conventional mechanical ventilation in the rabbit model of acute lung injury
BACKGROUND The use of positive end expiratory pressure (PEEP) in patients with acute lung injury (ALI) improves arterial oxygenation by alleviating pulmonary shunting, helping the respiratory muscles to decrease the work of breathing, decreasing the rate of infiltrated and atelectatic tissues, and increasing functional residual capacity. In a rabbit model of saline lavage-induced ALI, we examin...
متن کاملComparison of the effects of high frequency oscillation and controlled mechanical ventilation on hyaline membrane formation in a rabbit model of the neonatal respiratory distress syndrome.
Saline lavage of the lungs of eight anaesthetized New Zealand White rabbits was performed to produce a surfactant-depletion model of the neonatal respiratory distress syndrome. A characteristic change in the shape of the pressure-volume curve occurred, with the appearance of an inflection point on the inspiratory limb. The animals were treated with high frequency oscillation (HFO) at 15 Hz and ...
متن کاملInfluence of end-expiratory lung volume on carbon dioxide elimination during high frequency ventilation in dogs.
We have examined the effect of varying end-expiratory lung volume on carbon dioxide elimination in 10 mongrel dogs undergoing conventional mechanical ventilation at 12 b.p.m. and forced diffusion ventilation (FDV) at 6 Hz and 50 Hz and continuous flow. End-expiratory volumes were altered by changing the pressure in a plethysmographic box in which the dogs underwent ventilation. The pressures st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 63 7 Suppl 1 شماره
صفحات -
تاریخ انتشار 1989