Electrocardiographic changes during pressure breathing.

نویسنده

  • R J SHEPHARD
چکیده

It was recognized many years ago that the form of the electrocardiogram could be modified by a voluntary increase of breathing pressure, as during the Valsalva manceuvre (Kahn, 1909). During the early part of the second world war further studies were undertaken by German workers (Zettel and Fink, 1939; Muller, 1941), and it was found that it was altered even by the small fluctuations of breathing pressure associated with the wearing of a gas mask. At the altitudes of interest to modern aviation physiology, quite high positive breathing pressures may be necessary for survival, and such pressures produce dramatic alterations (Howard et al., 1953; R.C.A.F., 1954), including occasional abnormalities of rhythm, and a consistent change in the standard limb leads interpreted as clockwise rotation (Howard et al., 1953) or more cautiously as right axis deviation (R.C.A.F., 1954). The alteration in electrical axis is of particular interest: it offers a new technique for analysing the theoretical background to certain features of the electrocardiogram, and may also provide objective evidence of the success with which various counterpressure garments maintain normal anatomical relationships during pressure breathing. The present paper reports some measurements of the manifest electrical axis made during pressure breathing (with and without trunk counter-pressure) and during venous occlusion. Findings are correlated with other circulatory and respiratory changes observed during pressure breathing. The concept of a clockwise rotation of the heart in the frontal plane is confirmed, and it is concluded the electrocardiogram may indicate at least the order of this change.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Breathing Exercises on Breathing Pattern of Pregnant Women

Purpose: Physiological changes during pregnancy impose numerous changes on the respiratory system that can affect the health of both mother and fetus. Regarding the importance of the normal breathing in the health of mother and fetus, this study aimed to investigate the effect of breathing exercise on breathing pattern of pregnant women.  Methods: The study population was pregnant women...

متن کامل

Effect of changes in the breathing mode and body position on tongue pressure with respiratory-related oscillations.

The purpose of this study was to examine whether tongue pressure on the lingual surface of the mandibular incisors shows respiratory-related changes, with particular attention paid to its relationship to genioglossus electromyographic activity, and to determine the effect of changes in the mode of breathing and body position on tongue pressure. Tongue pressure was recorded with a miniature pres...

متن کامل

Respiratory challenge induces high frequency spiking on the static charge sensitive bed (SCSB).

The static charge sensitive bed (SCSB) is a simple and noninvasive device used for the detection of sleep apnoea. In addition to episodes of apnoea or hypopnoea, heavy snorers commonly present with episodes of high frequency spiking on the SCSB. These spiking episodes have been claimed to represent partial upper airway obstruction during sleep, but the mechanism of their appearance is not known...

متن کامل

THE EFFECT OF ARTERIAL O2 SATURATION AND HE ART RATE ON BLOOD PRESSURE DURING HYPOXIA

A periodic increase in blood pressure (BP) occurs during apneic episodes in patients with obstructive sleep apnea (OSA). Several factors including hypoxemia and an increase in heart rate (HR) were reported to be responsible for this increased BP. To examine the contribution of these two factors in increasing BP, 35 healthy male subjects (mean age±SD= 23.64±3.80) were studied in three experi...

متن کامل

Electrocardiographic changes in patients with cutaneous leishmaniasis treated with systemic Glucantime

Background and aim: Antimonial compounds are regarded as the treatment of choice for cutaneous leishmaniasis (CL). Systemic administration of these drugs have some side effects such as cardiotoxicity. The objective of this study was to evaluate the electrocardiographic (ECG) changes in patients with CL treated with systemic Glucantime.Materials and methods: This study w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 1957