Spectroscopy with Multichannel Correlation Radiometers

نویسنده

  • A. I. Harris
چکیده

Correlation radiometers make true differential measurements in power with high accuracy and small systematic errors. This receiver architecture has been used in radio astronomy for measurements of continuum radiation for over 50 years; this article examines spectroscopy over broad bandwidths using correlation techniques. After general discussions of correlation and the choice of hybrid phase experimental results from tests with a simple laboratory multi-channel correlation radiometer are shown. Analysis of the effect of the input hybrid’s phase shows that a 90◦ hybrid is likely to be the best general choice for radio astronomy, depending on its amplitude match and phase flatness with frequency. The laboratory results verify that the combination of the correlation architecture and an analog lag correlator is an excellent method for spectroscopy over very wide bandwidths.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ozone and UV radiation over southern South America: climatology and anomalies.

Ozone and UV radiation were analyzed at eight stations from tropical to sub-Antarctic regions in South America. Ground UV irradiances were measured by multichannel radiometers as part of the Inter American Institute for Global Change Radiation network. The irradiance channels used for this study were centered at 305 nm (for UV-B measurements) and 340 nm (for UV-A measurements). Results were pre...

متن کامل

Multichannel radiometer calibration: a new approach.

The error in irradiance measured with Sun-calibrated multichannel radiometers may be large when the solar zenith angle (SZA) increases. This could be particularly detrimental in radiometers installed at mid and high latitudes, where SZAs at noon are larger than 50 degrees during part of the year. When a multiregressive methodology, including the total ozone column and SZA, was applied in the ca...

متن کامل

Exploring effective multiplicity in multichannel functional near-infrared spectroscopy using eigenvalues of correlation matrices.

Recent advances in multichannel functional near-infrared spectroscopy (fNIRS) allow wide coverage of cortical areas while entailing the necessity to control family-wise errors (FWEs) due to increased multiplicity. Conventionally, the Bonferroni method has been used to control FWE. While Type I errors (false positives) can be strictly controlled, the application of a large number of channel sett...

متن کامل

Calibration of Correlation Radiometers Using Pseudo-Random Noise Signals

The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers' outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers ...

متن کامل

Time-to-Digital Converter card for multichannel time-resolved Single-Photon Counting applications

We present a high performance Time-to-Digital Converter (TDC) card that provides 10 ps timing resolution and 20 ps (rms) timing precision with a programmable full-scale-range from 160 ns to 10 μs. Differential Non-Linearity (DNL) is better than 1.3% LSB (rms) and Integral Non-Linearity (INL) is 5 ps rms. Thanks to the low power consumption (400 mW) and the compact size (78 mm x 28 mm x 10 mm), ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006