Development of a Fire-Induced Flashover Probability Index (FIFPI) for Eskom Transmission Lines

نویسندگان

  • P Frost
  • H Vosloo
  • J Meeuwis
چکیده

The need for a fire-induced flashover probability index (FIFPI) for Eskom’s transmission lines (South Africa) became evident soon after the installation the Advanced Fire Information System (AFIS) in 2004. Thousands of wildfires were detected by satellites close to transmission lines, but only a small percentage (4%) of these fires caused a flashover. Historical flashover data was compared to satellite fire information as well as air temperature, relative humidity, wind speed and wind direction within a logistic regression analysis to develop a flashover prediction model. The FIFPI model was able to predict problem fires with a misclassification cost of only 3.87%. The aim of this study was to develop a prediction model with the ability to accurately predict fire-induced flashover occurrences on Eskom transmission lines in order to reduce the large amount of false alarms (SMS and email messages) produced annually by AFIS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designation of an Indicator for flashover prediction of porcelain and glass insulators based on experimental tests.

Flashover of polluted insulators in contaminated areas is one of the most important factors influencing the operation of transmission and distribution lines and finally line outages. Therefore, it is essential to prevent and detect flashover in the insulators. Hence, utilizing the insulator status monitoring systems and predicting their functions have absorbed a lot of attention over the recent...

متن کامل

Fire Alerts on the Geospatial Semantic Web

CSIR is a South African research institution with broad and extensive experience in the domain of fire, ranging from policy work to basic research into fire and ecology. One of the more visible fire-related applications that CSIR has been involved in is known as the Advanced Fire Information System (AFIS), a joint initiative with Eskom, the South African electricity utility. The application uti...

متن کامل

Measurement of Electrical Conductivity for a Biomass Fire

A controlled fire burner was constructed where various natural vegetation species could be used as fuel. The burner was equipped with thermocouples to measure fuel surface temperature and used as a cavity for microwaves with a laboratory quality 2-port vector network analyzer to determine electrical conductivity from S-parameters. Electrical conductivity for vegetation material flames is import...

متن کامل

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....

متن کامل

PDF Based Icing Image Recognition Applied to Online Early Warning System for Transmission Lines

This paper proposes an online early warning technique and the probability distribution function (PDF) based icing image recognition for overhead power transmission lines. The main functionality of the online early warning system for overhead transmission lines firstly suggested in this paper is the early warning of icing, forest fire, lighting, insulator flashover, conductor galloping and invas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -