Surgical correction of distal radius malunions using an anatomic radial locking plate.
نویسندگان
چکیده
BACKGROUND Correction of a distal radius fracture malunion is challenging technically. These malunions most classically deform dorsally, but often the deformity involves three planes. METHODS Using an anatomically designed radial plate that takes into consideration the three planes, correction of the deformity can be obtained. In this video we see a patient with a classic dinner fork deformity that is associated with a dorsal malunion involving the distal radius. Correction of a distal radius malunion can be performed using a radial approach and an anatomic radial plate. RESULTS The authors have used this technique for difficult distal radius fracture malunions and have achieved superb correction, returning patients to early range of motion and an active lifestyle. CONCLUSIONS Careful mobilization of the branches of the lateral antebrachial cutaneous nerve and the superficial branch of the radial nerve is required. This technique affords the surgeon excellent access to three sides of the radius to help perform this complex surgery.
منابع مشابه
Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy
We report a 38-year-old male with a nonunion followed by plate breakage after volar plating of a distal radius osteotomy. Volar locking plates have added a new approach to the treatment of distal radius malunions, due to a lower morbidity of the surgical approach and the strength of the final construction, allowing early mobilization and return to function. Conclusion. Plate breakage is an unco...
متن کاملDistal radius measurements and efficacy of fixed-angle locking volar plates.
AIM For surgical treatment of unstable distal radius fractures, fixed-angled locking volar plate fixation is becoming popular nowadays because of some advantages over other surgical techniques. In this article, we discuss the fitting of fixed-angle locking volar plates to the distal radius in relation to the changes in the distal radial angles. MATERIALS AND METHODS First, we took conventiona...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملCorrection osteotomy of distal radius malunion stabilised with dorsal locking plates without grafting
The purpose of this study was to evaluate the results of our correction osteotomies of distal radial malunions without a bone graft. Eleven consecutive patients (mean age 52 years, range 18-71) were treated. A dorsal approach was utilised to perform an opening-wedge osteotomy which then was stabilised with two dorsal columnar plates without filling the osteotomy gap. All patients went on to rad...
متن کاملThree-dimensional correction of distal radius intra-articular malunions using patient-specific drill guides.
PURPOSE To analyze the feasibility of combining computer-assisted 3-dimensional planning with patient-specific drill guides and to evaluate this technology's surgical outcomes for distal radius intra-articular malunions. METHODS Six symptomatic patients with intra-articular malunions of the distal radius with a stepoff of more than 2 mm were treated with an outside-in corrective osteotomy. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hand
دوره 10 4 شماره
صفحات -