Levetiracetam (LEV), an antiepileptic drug (AED) with favorable pharmacokinetic profile, is increasingly being used in clinical practice, although information on its metabolism and disposition are still being generated. Therefore a simple, robust and fast liquid-liquid extraction (LLE) followed by highperformance liquid chromatography method is described that could be used for both pharmacokinetic and therapeutic drug monitoring (TDM) purposes. Moreover, recovery rates of LEV in plasma were compared among LLE, stir bar-sorptive extraction (SBSE), and solid-phase extraction (SPE). Solvent extraction with dichloromethane yielded a plasma residue free from usual interferences such as commonly co-prescribed AEDs, and recoveries around 90% (LLE), 60% (SPE) and 10% (SBSE). Separation was obtained using reverse phase Select B column with ultraviolet detection (235 nm). Mobile phase consisted of methanol:sodium acetate buffer 0.125 M pH 4.4 (20:80, v/v). The method was linear over a range of 2.8-220.0 μg mL-1. The intraand inter-assay precision and accuracy were studied at three concentrations; relative standard deviation was less than 10%. The limit of quantification was 2.8 μg mL-1. This robust method was successfully applied to analyze plasma samples from patients with epilepsy and therefore might be used for pharmacokinetic and TDM purposes.
منابع مشابه
Stir bar sorptive extraction coupled to liquid chromatography-tandem mass spectrometry for the determination of pesticides in water samples: method validation and measurement uncertainty.
Stir bar sorptive extraction followed by liquid desorption and high performance liquid chromatography with tandem mass spectrometry (SBSE-LD-LC-MSMS) has been developed for the determination of 15 pesticides or selected metabolites from different families (herbicides, insecticides, fungicides) in surface water samples. The optimization of parameters that could influence SBSE-LD efficiency was c...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملA new rotating-disk sorptive extraction mode, with a copolymer of divinylbenzene and N-vinylpyrrolidone trapped in the cavity of the disk, used for determination of florfenicol residues in porcine plasma.
A novel extraction approach was developed based on rotating-disk sorptive extraction (RDSE). In this approach the rotating-disk extraction device consists of a Teflon disk, with a cavity that is loaded with a commercial sorbent phase selected according to the polarity of the analyte. To avoid leakage of the sorbent, the cavity is covered with a fiberglass filter and sealed with a Teflon ring. T...
متن کاملMolecularly Imprinted Stir Bar Sorptive Extraction Coupled with High-Performance Liquid Chromatography for Trace Analysis of Diclofenac in Different Real Samples
A novel molecularly imprinted polymer-coated stir bar has been used to selectively extract diclofenac (DFC) directly from real samples. DFC was used as template molecule for preparation of MIP coating. The effect of different parameters on the extraction efficiency were studied and the optimum conditions were established as: the absorption and desorption times were fixed at 10 min, stirring...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015