Risk-shifting, and Natural Gas Pipeline Regulation
نویسندگان
چکیده
منابع مشابه
محاسبه ریسک و مدل سازی پیامد حادثه نشت گاز طبیعی با استفاده از نرم افزار ALOHA
Introduction: Fire and explosion are the most common consequences of natural gas pipeline accidents. The results of previous studies showed a higher rate of accidents in natural gas transmission lines. Given that a large number of people living in the vicinity of natural gas pipelines with a higher severity of related accidents. The aim of current study was to estimate risks using the method of...
متن کاملارزیابی ریسک شبکه توزیع گاز شهری با استفاده از تحلیل سلسله مراتبی در شهر سنندج
Background and Aims: Natural gas pipeline network is an important part of a city’s infrastructure for energy transmission. As the gas pipeline network becoming vaster and more complex, accident caused by the leak of gas pipeline network occur. Accidents consequences caused by gas pipeline rupture, can directly threatening the safety of persons and properties in the city. Thus, it is neces...
متن کاملPredictive Control of Gas Injection in Natural Gas Transport Networks
The present sought to draw a comparison between Model Predictive Control performance and two other controllers named Simple PI and Selective PI in controlling large-scale natural gas transport networks. A nonlinear dynamic model of representative gas pipeline was derived from pipeline governing rules and simulated in SIMULINK® environment of MATLAB®. Control schemes were designed to provide a s...
متن کاملQualitative Risk Assessment of Gas Pipelines by Using of Indexing System Method in GIS environment
Nowadays the urbanization is developing rapidly, and it leads to growing demand for gas; which resulted in denser pipeline network, by the following increase in the pipeline network congestion, accidents will become inevitable. So Pipelines are a remarkable source of hazard for their adjacent society. Usually Indexing system method is used for pipe line risk assessment. This method assesses ri...
متن کاملExperimental values for adjusting an automatic control valve in gas pipeline transportation
When a natural gas pipeline ruptures, the adjacent automatic line control valves (ALCVs) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ALCV action. If the DPS is not properly adjusted, the ALCV may mistakenly close or it may not take any action at proper time. This study focused on...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008