Comparative study of 99mTc-ECD and 99mTc-HMPAO for peri-ictal SPECT: qualitative and quantitative analysis.

نویسندگان

  • T J O'Brien
  • B H Brinkmann
  • B P Mullan
  • E L So
  • M F Hauser
  • M K O'Connor
  • J Hung
  • C R Jack
چکیده

OBJECTIVES Most studies that clinically validated peri-ictal SPECT in intractable partial epilepsy had used technetium-99m-hexamethylpropylene amine oxime (99mTc-HMPAO or 99mTc-exametazime) as the radiopharmaceutical. Because of some theoretical advantages, technetium-99m-ethyl cysteinate diethylester (99mTc-ECD or 99mTc-bicisate) is increasingly being used instead. This study compares unstabilised 99Tc-HMPAO and 99mTc-ECD in the performance of peri-ictal SPECT in partial epilepsy. METHODS The injection timing and localisation rates in 49 consecutive patients with partial epilepsy who had peri-ictal injections with unstabilised 99mTc-HMPAO were compared with 49 consecutive patients who had peri-ictal injections with 99mTc-ECD. Quantitative cortical/subcortical and cortical/extracerebral uptake ratios were also compared. Subtraction SPECT coregistered to MRI (SISCOM) was performed in patients whose interictal SPECTS were available. RESULTS In the 99mTc-ECD patients, the latency from seizure commencement to injection was shorter (median 34 v 80 seconds, p<0.0001) and there was a lower rate of postictal injections (16.3% v 57.1%, p<0.0001). The cortical/extracerebral and cortical/subcortical uptake ratios were greater in the 99mTc-ECD images (median 5.0 v 3.6, and 2.5 v 2.2 respectively; both p<0.005), but the relative peri-ictal increase in uptake in the cortical focus did not differ significantly (median 37.0% v 37.0%; p>0.05). Blinded review of the SISCOM images were localising in a higher proportion of the 99mTc-ECD patients (40/45 (88.9%) v 25/37 (67.6%), p<0.05), and had a better concordance with EEG, MRI, and with the discharge diagnosis. CONCLUSION 99mTc-ECD compares favourably with unstabilised 99mTc-HMPAO as a radiopharmaceutical for peri-ictal SPECT studies. Its use results in earlier injections and less frequent postictal injections than unstabilised 99mTc-HMPAO, thereby enhancing the sensitivity and the specificity of peri-ictal SPECT for the localisation of intractable partial epilepsy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brain single-photon emission CT studies using 99mTc-HMPAO and 99mTc-ECD early after recanalization by local intraarterial thrombolysis in patients with acute embolic middle cerebral artery occlusion.

BACKGROUND AND PURPOSE The brain distribution of 9mTc-hexamethylpropyleneamine oxime (HMPAO) correlates with regional brain perfusion, whereas 99mTc-ethyl cysteinate dimer (ECD) reflects not only perfusion but also the metabolic status of brain tissue. We compared 99mTc-ECD single-photon emission CT (SPECT) with 99mTc-HMPAO SPECT early after recanalization by local intraarterial thrombolysis (L...

متن کامل

99mTc-bicisate and 99mTc-HMPAO SPECT imaging in early spontaneous reperfusion of cerebral embolism.

Two patients with a cerebral embolism were evaluated by using both 99mTc-ethyl cysteinate dimer (ECD, or Bicisate) and 99mTc-hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). In one patient, 99mTc-ECD SPECT images revealed hypoactivity in a reflow hyperemic area where an infarct was seen later on CT scans. In another patient, a reperfused area showed hyp...

متن کامل

Development of "super rapid dynamic SPECT," and analysis of retention process of 99mTc-ECD in ischemic lesions: comparative study with 133Xe SPECT.

To analyze the retention process of technetium-99m ethyl cysteinate dimer (99mTc-ECD) in normal and ischemic lesions, we developed a super rapid dynamic SPECT system based on the CERASPECT (DSI, Inc., Waltham, MA, USA). The system made it possible to take a SPECT series every 2 seconds. Each SPECT series contains a maximum of 16 slices (6.6 mm slice interval) in a matrix size of 32 x 32. The se...

متن کامل

Determination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging

Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...

متن کامل

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurology, neurosurgery, and psychiatry

دوره 66 3  شماره 

صفحات  -

تاریخ انتشار 1999