Permanent prostate seed implant brachytherapy: report of the American Association of Physicists in Medicine Task Group No. 64.
نویسندگان
چکیده
There is now considerable evidence to suggest that technical innovations, 3D image-based planning, template guidance, computerized dosimetry analysis and improved quality assurance practice have converged in synergy in modern prostate brachytherapy, which promise to lead to increased tumor control and decreased toxicity. A substantial part of the medical physicist's contribution to this multi-disciplinary modality has a direct impact on the factors that may singly or jointly determine the treatment outcome. It is therefore of paramount importance for the medical physics community to establish a uniform standard of practice for prostate brachytherapy physics, so that the therapeutic potential of the modality can be maximally and consistently realized in the wider healthcare community. A recent survey in the U.S. for prostate brachytherapy revealed alarming variance in the pattern of practice in physics and dosimetry, particularly in regard to dose calculation, seed assay and time/method of postimplant imaging. Because of the large number of start-up programs at this time, it is essential that the roles and responsibilities of the medical physicist be clearly defined, consistent with the pivotal nature of the clinical physics component in assuring the ultimate success of prostate brachytherapy. It was against this background that the Radiation Therapy Committee of the American Association of Physicists in Medicine formed Task Group No. 64, which was charged (1) to review the current techniques in prostate seed implant brachytherapy, (2) to summarize the present knowledge in treatment planning, dose specification and reporting, (3) to recommend practical guidelines for the clinical medical physicist, and (4) to identify issues for future investigation.
منابع مشابه
Comparison of implant quality between intraoperatively built custom-linked seeds and loose seeds in permanent prostate brachytherapy using sector analysis
We compared the implant quality of intraoperatively built custom-linked (IBCL) seeds with loose seeds in permanent prostate brachytherapy. Between June 2012 and January 2015, 64 consecutive prostate cancer patients underwent brachytherapy with IBCL seeds (n = 32) or loose seeds (n = 32). All the patients were treated with 144 Gy of brachytherapy alone. Brachytherapy was performed using a dynami...
متن کاملDetermination of TG-43 Dosimetric Parameters for Photon Emitting Brachytherapy Sources
Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...
متن کاملCode of practice for brachytherapy physics: report of the AAPM Radiation Therapy Committee Task Group No. 56. American Association of Physicists in Medicine.
Recommendations of the American Association of Physicists in Medicine (AAPM) for the practice of brachytherapy physics are presented. These guidelines were prepared by a task group of the AAPM Radiation Therapy Committee and have been reviewed and approved by the AAPM Science Council.
متن کاملA technical evaluation of the Nucletron FIRST system: Conformance of a remote afterloading brachytherapy seed implantation system to manufacturer specifications and AAPM Task Group report recommendations
The Fully Integrated Real-time Seed Treatment (FIRST) system by Nucletron has been available in Europe since November 2001 and is being used more and more in Canada and the United States. Like the conventional transrectal ultrasound implant procedure, the FIRST system utilizes an ultrasound probe, needles, and brachytherapy seeds. However, this system is unique in that it (1) utilizes a low-dos...
متن کاملModification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds
Background:Â A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective:Â The present study aims to modify source strength for different configurations of 125I and 103...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 26 10 شماره