Bandwidth improvement of LiNbO3 ultrasonic transducers by half-concaved inversion layer approach.
نویسندگان
چکیده
A novel type of half-concaved LiNbO(3) plate with domain inversion layer has been proposed for fabricating high-frequency broadband ultrasonic transducers. Two opposite ferroelectric polarization layers with a curved boundary are presented after heat treatment in the half-concaved LiNbO(3) plate with a total thickness of 110 μm. Characterization of the transducers illustrates that, without a matching layer, the self-focusing transducer with the half-concaved LiNbO(3) plate has achieved 123% bandwidth at the center frequency of 60 MHz, which is a significant improvement over the planar inversion layer transducer.
منابع مشابه
Design, Development and Characterization of Wideband Polymer Ultrasonic Probes for Medical Ultrasound Applications
Design, Development and Characterization of Wideband Polymer Ultrasonic Probes for Medical Ultrasound Applications Vadivel Devaraju Peter A. Lewin, Ph.D. This dissertation deals with the design, development and characterization of non-resonant polymer ultrasonic probes for medical ultrasound applications. Both single element and multielement imaging transducer design having single layer and mul...
متن کاملUltrahigh Frequency (100 MHz–300 MHz) Ultrasonic Transducers for Optical Resolution Medical Imagining
High resolution ultrasonic imaging requires high frequency wide band ultrasonic transducers, which produce short pulses and highly focused beam. However, currently the frequency of ultrasonic transducers is limited to below 100 MHz, mainly because of the challenge in precise control of fabrication parameters. This paper reports the design, fabrication, and characterization of sensitive broadban...
متن کاملModelling of a novel high-impedance matching layer for high frequency (>30 MHz) ultrasonic transducers.
This work describes a new approach to impedance matching for ultrasonic transducers. A single matching layer with high acoustic impedance of 16 MRayls is demonstrated to show a bandwidth of around 70%, compared with conventional single matching layer designs of around 50%. Although as a consequence of this improvement in bandwidth, there is a loss in sensitivity, this is found to be similar to ...
متن کامل44-MHz LiNbO3 transducers for UBM-guided Doppler ultrasound.
In the post genome-sequencing era, physiological phenotyping of genetically engineered mice is critical to further our understanding of the functional consequences of specific genetic defects. We have developed a 40-50 MHz ultrasound biomicroscopy-(UBM) guided, pulsed Doppler system for the sensitive detection of in vivo blood velocity waveforms in the mouse embryonic cardiovascular system. Our...
متن کاملBroadband and High Sensitive Time-of-Flight Diffraction Ultrasonic Transducers Based on PMNT/Epoxy 1–3 Piezoelectric Composite
5-6 MHz PMNT/epoxy 1-3 composites were prepared by a modified dice-and-fill method. They exhibit excellent properties for ultrasonic transducer applications, such as ultrahigh thickness electromechanical coupling coefficient k(t) (85.7%), large piezoelectric coefficient d33 (1209 pC/N), and relatively low acoustic impedance Z (1.82 × 107 kg/(m2·s)). Besides, two types of Time-of-Flight Diffract...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 83 11 شماره
صفحات -
تاریخ انتشار 2012