Evaluation of the relationship between capillary and venous plasma glucose concentrations obtained by the HemoCue Glucose 201+ system during an oral glucose

نویسندگان

  • Claes Ignell
  • Kerstin Berntorp
چکیده

In 55 women with previous gestational diabetes mellitus, simultaneous capillary and venous plasma glucose concentrations were measured at 0, 30 and 120 min during a 75 g oral glucose tolerance test (OGTT). The aims of the study were to examine the relationship between capillary and venous glucose measurements, and to establish equations for the conversion of capillary and venous glucose concentrations using the HemoCue Glucose 201+ system. Additionally, the correlation between the capillary and venous glucose concentrations with the diagnostic cut-off limits proposed by the WHO 1999 was evaluated. Capillary glucose concentrations were consistently higher than venous glucose concentrations at all time points of the OGTT (p < 0.001), and the correlations between the measurements were statistically highly significant (p < 0.001). The differences between the samples were greatest in the nonfasting state as revealed by the 95% prediction intervals (mmol/L) in Bland-Altman plots; ± 0.54 at 0 min, ± 2.01 at 30 min, and ± 1.35 at 120 min. Equivalence values for capillary plasma glucose concentrations derived from this study tended to be higher than those proposed by the WHO as diagnostic cut-off limits. Stratifying subjects by glucose tolerance status according to the WHO criteria revealed disagreements related to glucose values close to the diagnostic cut-off points. The study findings highlight the uncertainty associated with derived equivalence values. However, capillary plasma glucose measurements could be suitable for diagnostic purposes in epidemiological studies and when translating results on a group basis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Point of Care (POC) Testing of Glucose by B Braun Glucometer and Hemocue Glucose 201+ Analyser Versus Centralised Testing in Neonatal Intensive Care Unit (NICU).

BACKGROUND Neonatal hypoglycemia is the most common carbohydrate metabolic disturbance seen in case of neonates and especially in preterm neonates. Accurate and rapid determination of hypoglycemia and its prompt treatment is of utmost importance to decrease morbidity and mortality of neonates. AIMS To estimate blood glucose in neonates and test the efficacy of HemoCue Glucose 201+ analyser an...

متن کامل

Point-of-care testing of HbA1c and blood glucose in a remote Aboriginal Australian community.

OBJECTIVES To assess the accuracy of point-of-care (POC) measurements of capillary blood glucose and glycosylated haemoglobin (HbA(1c)) levels in a remote Aboriginal community with high diabetes prevalence. DESIGN Cross-sectional study comparing POC capillary glucose and HbA(1c) results with those from corresponding venous samples measured in a reference laboratory. PARTICIPANTS AND SETTING...

متن کامل

بررسی همخوانی نوارهای سنجش قند خون بتاچک با روش استاندارد

Diabetes mellitus (DM) is the commonest cause of renal failure, blindness and non traumatic amputation. According to ADA, prevention of DM complications is possible through monitoring and control of blood glucose levels.Methods: The Betachek strip, produced in Australia, is able to determine biood glucose level with no need for electronic glucometer devices.Results: In this study, we compared v...

متن کامل

HemoCue: evaluation of a portable photometric system for determining glucose in whole blood.

We assessed the HemoCue system for measuring glucose in 5 microL of whole blood. A glucose dehydrogenase-based reaction is used with dried reagents contained in disposable microcuvettes, which are filled with blood by capillary action. Automated hexokinase and YSI 23AM glucose analyzer methods were used for comparison. Overall imprecision (CV) was better than 4.5%, with no significant differenc...

متن کامل

The detection of salivary glucose, caries and periodontal status in diabetes ‎mellitus patients

OBJECTIVE: Oral manifestations in diabetic patients can have different causes. Possibly, one of these causes is salivary glucose. The aim of this study was to evaluate salivary glucose concentrations in patients with Type II diabetes mellitus (DM) and their association with oral and dental manifestations and compare them with normal adults. MATERIALS AND METHODS: In this analytical study, 128 p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017