Prospective head-movement correction for high-resolution MRI using an in-bore optical tracking system.
نویسندگان
چکیده
In MRI of the human brain, subject motion is a major cause of magnetic resonance image quality degradation. To compensate for the effects of head motion during data acquisition, an in-bore optical motion tracking system is proposed. The system comprises two MR-compatible infrared cameras that are fixed on a holder right above and in front of the head coil. The resulting close proximity of the cameras to the object allows precise tracking of its movement. During image acquisition, the MRI scanner uses this tracking information to prospectively compensate for head motion by adjusting the gradient field direction and radio frequency (RF) phases and frequencies. Experiments performed on subjects demonstrate robust system performance with translation and rotation accuracies of 0.1 mm and 0.15 degrees, respectively.
منابع مشابه
Prospective Head Movement Correction for High-resolution MRI Using a Single Camera
Introduction The image quality of brain MRI scans can be compromised by head motion. Prospective motion correction based on external tracking systems has been proposed to ameliorate this issue. Stereo optical tracking systems have been shown to give good real-time motion correction with reasonable accuracy [1,2]. However, the accurate calibration for the stereo system as well as the calibration...
متن کاملProspective motion correction of 3D echo-planar imaging data for functional MRI using optical tracking
We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and ...
متن کاملKnee cartilage MRI with in situ mechanical loading using prospective motion correction.
PURPOSE To assess the feasibility of high resolution knee cartilage MRI with in situ mechanical loading using optical tracking to compensate for motion. METHODS In vivo cartilage MRI with in situ mechanical loading is demonstrated on a clinical 3T system for the patellofemoral as well as for the tibiofemoral knee joint using a T1-weighted spoiled three-dimensional gradient-echo sequence. Pros...
متن کاملAn evaluation of prospective motion correction (PMC) for high resolution quantitative MRI
Quantitative imaging aims to provide in vivo neuroimaging biomarkers with high research and diagnostic value that are sensitive to underlying tissue microstructure. In order to use these data to examine intra-cortical differences or to define boundaries between different myelo-architectural areas, high resolution data are required. The quality of such measurements is degraded in the presence of...
متن کاملAn adaptive MR-compatible lens
Introduction We present an MR-compatible adaptive membrane lens, which is integrated into a wide-angle objective to form part of an optical tracking system. This work is motivated by the need for optical head tracking devices for use in prospective motion correction [1], but an alternative application could be high-resolution eye tracking for fMRI. The challenge for in-bore cameras is the limit...