Use of sequential Heidelberg retina tomograph images to identify changes at the optic disc in ocular hypertensive patients at risk of developing glaucoma.

نویسندگان

  • D S Kamal
  • D F Garway-Heath
  • R A Hitchings
  • F W Fitzke
چکیده

AIM To determine if global and segmental changes in optic disc parameters of sequential Heidelberg retina tomograph (HRT) images develop in individual ocular hypertensive (OHT) patients without white on white visual field defects. METHODS Patients and normal controls were recruited from a prospective ocular hypertension treatment trial. The subject groups consisted of 21 OHT patients who had converted to early glaucoma on the basis of visual field criteria (24-2 program on the Humphrey perimeter), 164 OHT subjects with normal visual fields, and 21 normal controls. Sequential HRT images 16-21 months apart were obtained for each subject and segmental optic disc parameters were measured to determine if any change had occurred. From the analysis of sequential HRT images of the 21 normal eyes we established normal limits of interimage variation. Individual discs in each group showing changes above the 95% limit of normal variability were then sought. RESULTS Several segmental and global optic disc parameters were found to show significant change in the converter group before confirmed visual field change, confirming our previously published results. Individual optic disc analysis using the 95% limit of normal variability data demonstrated glaucomatous change in 13 out of 21 converter eyes. 47 of the 164 OHT eyes with normal visual fields showed change in global and segmental parameters in a "glaucomatous" direction above the level expected for normal variability. The parameters which changed most frequently in the OHT eyes were: global cup volume (6.7% of discs), inferonasal cup volume (11%), inferotemporal cup volume (8.5%), and superotemporal cup area (7.3%). CONCLUSIONS We have identified change in a subset of ocular hypertensive patients which could predate the development of glaucomatous visual field loss. The HRT could be of value in the sequential follow up of those suspected of having glaucoma by identifying eyes at risk of developing glaucoma. However, further refinement of the technique is required to eliminate some of the inherent variability of the analysis method described, and to increase the ability to detect at risk individuals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of optic disc change with the Heidelberg retina tomograph before confirmed visual field change in ocular hypertensives converting to early glaucoma.

AIM To determine whether analysis of sequential optic disc images obtained with the Heidelberg retina tomograph (HRT) is able to demonstrate optic disc change before the development of reproducible field defects in a group of ocular hypertensive (OHT) patients converting to early glaucoma. METHODS Two groups were analysed: (1) 13 eyes of 13 OHT patients who subsequently developed reproducible...

متن کامل

[Relationship between standard automated perimetry and optic nerve head topography performed with the Heidelberg Retina Tomograph].

PURPOSE To determine the correlations between optic nerve head (ONH) parameters measured with the Heidelberg Retina Tomograph (HRT), and the main outcomes of standard automated perimetry (SAP) in normal, ocular hypertensive, glaucoma suspects and glaucomatous subjects. METHODS Four hundred and twenty-three patients were enrolled in the study and classified into four groups depending on baseli...

متن کامل

CLINICAL SCIENCE Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph

Aims: To assess the intraobserver agreement, interobserver agreement, and the agreement between a digital stereo optic disc camera (Discam) and Heidelberg retina tomograph (HRT) in measuring area cup-disc ratio (ACDR) and radial cup-disc ratio (RCDR) by two observers. Methods: The optic discs of 78 eyes of 39 people (17 cases of primary open angle glaucoma, eight normal tension glaucoma, two oc...

متن کامل

Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph.

AIMS To assess the intraobserver agreement, interobserver agreement, and the agreement between a digital stereo optic disc camera (Discam) and Heidelberg retina tomograph (HRT) in measuring area cup-disc ratio (ACDR) and radial cup-disc ratio (RCDR) by two observers. METHODS The optic discs of 78 eyes of 39 people (17 cases of primary open angle glaucoma, eight normal tension glaucoma, two oc...

متن کامل

Factors affecting the variability of the Heidelberg Retina Tomograph III measurements in newly diagnosed glaucoma patients.

PURPOSE To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were exc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 84 9  شماره 

صفحات  -

تاریخ انتشار 2000