Characterization and financial impact of implantable cardioverter-defibrillator patients without interventions 5 years after implantation.
نویسندگان
چکیده
BACKGROUND Implantable cardioverter defibrillators (ICD's) are increasingly used for primary and secondary prevention of sudden cardiac death. However, data on how many ICD patients indeed receive appropriate ICD therapy during long-term follow-up is scarce. AIM The aim of our study was to determine the number of patients without appropriate ICD therapy 5 years after ICD implantation, to identify predicting factors, to assess the occurrence of late first ICD therapy and to quantify the financial impact of ICD therapy in a real-world setting. DESIGN Prospective observational study. METHODS We prospectively enrolled 322 consecutive ICD patients. Baseline data were collected at implantation and patients were followed for a median of 7.3 years (IQR 5.8-9.2 years). Time to first appropriate ICD therapy (either antitachycardia pacing or cardioversion) was documented. RESULTS Five years after implantation, 139 patients (43%) had not received appropriate ICD therapy. In multivariable analysis, a primary prevention indication and negative electrophysiological studies prior to ICD implantation were independent predictors of freedom from ICD therapy. Of the patients without ICD therapy, 5 years after implantation, 25% had experienced inappropriate ICD shocks. Two hundred and seven devices (1.5 devices per patient) were needed for the 139 patients without ICD intervention within 5 years, accounting for € 31,784 per patient. During an additional follow-up of 3 years, 12% of the patients with unused ICD received a late first appropriate ICD therapy. CONCLUSION About half of the ICD patients receive appropriate ICD therapy within 5 years after implantation. Furthermore, there is a significant proportion of patients receiving late first shocks after five initially uneventful years.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملThe effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)
Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...
متن کاملImpact of the implantable cardioverter-defibrillator on rehospitalizations.
UNLABELLED Patients who survive out-of-hospital ventricular tachycardia or ventricular fibrillation are at risk of sudden cardiac death and often return to hospital after initial discharge. The frequency and duration of readmittance to hospital are not well known. Thus, the purpose of this study was to evaluate the impact of the implantable cardioverter defibrillator on frequency and duration o...
متن کاملتأثیر آموزش مبتنی بر الگوی خودمراقبتی اورم بر توان خودمراقبتی بیماران دارای دفیبریلاتور قلبی قابل کاشت (ICD)
Background & Aim: Several studies have shown that the self-care activity of patients with implantable cardioverter defibrillator is inadequate. This study was conducted to assess the effect of an educational program based on the Orem’s self-care model in self-care ability of the patients . Methods & Materials: This clinical trial was conducted among 66 patients with implantable cardiove...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- QJM : monthly journal of the Association of Physicians
دوره 104 10 شماره
صفحات -
تاریخ انتشار 2011