Continuous signal enhancement for sensitive aptamer affinity probe electrophoresis assay using electrokinetic concentration.

نویسندگان

  • Lih Feng Cheow
  • Jongyoon Han
چکیده

We describe an electrokinetic concentration-enhanced aptamer affinity probe electrophoresis assay to achieve highly sensitive and quantitative detection of protein targets in a microfluidic device. The key weaknesses of aptamer as a binding agent (weak binding strength/fast target dissociation) were counteracted by continuous injection of fresh sample while band-broadening phenomena were minimized due to self-focusing effects. With 30 min of continuous signal enhancement, we can detect 4.4 pM human immunoglobulin E (IgE) and 9 pM human immunodeficiency virus 1 reverse transcriptase (HIV-1 RT), which are among the lowest limits of detection (LOD) reported. IgE was detected in serum sample with a LOD of 39 pM due to nonspecific interactions between aptamers and serum proteins. The method presented in this paper also has broad applicability to improve sensitivities of various other mobility shift assays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a concentration-enhanced mobility shift assay platform for aptamer-based biomarker detection and kinase profiling

New methods to quantify rare biomarkers from patient samples are critical for developing pointof-care diagnostic platforms. To be compatible with resource limited settings, these assays have to provide fast and accurate results without sacrificing ease of use. Biosensing in homogeneous fashion is the preferred format which satisfies these criteria, but the lack of amplification method is a bott...

متن کامل

A label-free thrombin binding aptamer as a probe for highly sensitive and selective detection of lead(II) ions by a resonance Rayleigh scattering method.

The binding of lead(II) ions with unusually high affinity to a thrombin binding aptamer resulted in an enhancement of resonance Rayleigh scattering (RRS). A simple, sensitive, and selective assay for the direct determination of trace amounts of Pb(2+) on the basis of RRS has been proposed.

متن کامل

Diffractometric detection of proteins using microbead-based rolling circle amplification.

We present a robust, sensitive, fluorescent- or radiolabel-free self-assembled optical diffraction biosensor that utilizes rolling circle amplification (RCA) and magnetic microbeads as a signal enhancement method. An aptamer-based sandwich assay was performed on microcontact-printed streptavidin arranged in 15 microm wide alternating lines and could specifically capture and detect platelet-deri...

متن کامل

Highly sensitive protein detection based on aptamer probe and isothermal nicking enzyme assisted fluorescence signal amplification.

An isothermal and sensitive fluorescence assay for protein detection using aptamer-protein-aptamer conjugates based on nicking enzyme amplification has been developed, which was combined with magnetic microparticles separation, making this assay suitable for protein detection in biological samples.

متن کامل

Affinity analysis of a protein-aptamer complex using nonequilibrium capillary electrophoresis of equilibrium mixtures.

We propose a new method that allows the use of low-affinity aptamers as affinity probes in quantitative analyses of proteins. The method is based on nonequilibrium capillary electrophoresis of the equilibrium mixture (NECEEM) of a protein with its fluorescently labeled aptamer. In general, NECEEM of a protein with a fluorescently labeled aptamer generates an electropherogram with three characte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 83 18  شماره 

صفحات  -

تاریخ انتشار 2011