Endoscopic intraluminal cutting technique for indwelling devices using a lithotripter handle and guidewire.

نویسندگان

  • Yu Muta
  • Yoshihiro Nishikawa
  • Kotaro Watanabe
  • Koichiro Kawano
  • Hiroshi Seno
  • Tsutomu Chiba
  • Shujiro Yazumi
چکیده

Many transmural endoscopic devices have been developed for various different procedures; however, few options exist to endoscopically process these indwelling devices once they have been positioned. Here, we introduce a novel technique that allows indwelling devices to be cut endoscopically using a combination of an endoscopic retrograde cholangiopancreatography (ERCP) lithotripter handle and a guidewire, as illustrated in these two patients. The procedure is performed as follows: (i) an ERCP guidewire (VisiGlide 0.025 inch; Olympus, Tokyo, Japan) is inserted through a therapeutic endoscope (GIF-1T240; Olympus) and is looped around the indwelling device using a biopsy forceps (FB-45Q-1; Olympus) (●" Fig.1a); (ii) a lithotripter cable (Conquest TTCL-1; Cook Japan Inc., Tokyo, Japan) is inserted over the guidewire up to the indwelling device (●" Fig.1b); (iii) the guidewire and the cable are connected to the lithotripter handle (Soehendra; Cook Japan Inc.) (●" Fig.1c); (iv) the guidewire is reeled in using the handle, until the tightened loop of the guidewire cuts through the indwelling device (●" Video 1). Fig.1 Photographs showing: a a loop made with the guidewire around the “indwelling” device; b the lithotripter cable inserted over the guidewire; c the guidewire and the cable connected to the handle.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic Removal of Migrated Laparoscopic Adjustable Gastric Band Using a Soehendra Lithotriptor® and a Guidewire

Laparoscopic adjustable gastric banding is an effective and popular treatment for morbid obesity. However, migration of the gastric band into the gastric lumen could be a late complication of the procedure. Migrated gastric bands’ removal from the stomach is mandatory to preclude adverse events. The treatment of band migration has classically been surgical. Nonetheless, endoscopic removal is fe...

متن کامل

Uneven double-lumen cannula for rescue guidewire technique in endoscopic ultrasonography-guided hepaticogastrostomy.

Endoscopic ultrasonography-guided hepaticogastrostomy (EUS-HGS) is used after failed endoscopic retrograde cholangiopancreatography (ERCP) [1]. Manipulation of the guidewire is one of the most challenging techniques in EUSHGS.We present a successful case of rescue guidewire technique using a multilumen catheter [2], namely an uneven double-lumen cannula (Piolax Medical Devices, Yokohama, Kanaga...

متن کامل

Stubborn stones: breakages of a mechanical lithotripter by an exceptionally hard gallstone.

To cite: Allen N, Pettit S, Ali A. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2014204940 DESCRIPTION Endoscopic retrograde cholangiopancreatography (ERCP) is the predominate method of removing common bile duct (CBD) calculi. The simplest and quickest way of removing large CBD calculi during ERCP is a mechanical lithotripter to crush the gallstone before remov...

متن کامل

Surgical Gastrostomy Based on Endoscopic Concepts.

BACKGROUND Until the early 1980s, Stamm technique was considered standard method to gastrostomy. After description of the endoscopic technique, due to its efficiency and speed, quickly became the method of choice for long-term enteral access. AIM Describe a technique that combines direct view of the stomach from open surgery with the simplicity and less traumatic endoscopic gastrostomy method...

متن کامل

EUS-guided transmural drainage for peripancreatic fluid collections using fine needle and stiff fine guidewire without electrocautery: An optional safe technique

Endoscopic transmural drainage by using endoscopic ultrasound (EUS) guidance is not always safe because of the risk of bleeding and perforation. Additionally, the effective area of the EUS-guided procedure using a large diameter needle is relatively narrow. We evaluated the effectiveness and safety of EUS-guided drainage using fine needle and stiff fine guidewire without electrocautery. From No...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Endoscopy

دوره 47 Suppl 1 UCTN  شماره 

صفحات  -

تاریخ انتشار 2015