Short-Term Results of Novel Constrained Total Hip Arthroplasty
نویسندگان
چکیده
Constrained acetabular components have only been recommended as a salvage option for the persistently unstable total hip arthroplasty (THA), due to limited range of motion and less than satisfactory component failure rates. This is a retrospective review of 137 patients with 154 consecutive primary constrained THAs performed between November 2003 and August 2007. We reviewed serial radiographs, postoperative complications, groin/thigh pain, and compared preoperative and postoperative Harris Hip Scores. With a mean follow-up of 6 years, there was 1.9% dislocation rate, 0% component failure rate, and 2.6% infection rate. Seven patients reported continued groin pain, and three had continued thigh pain. One patient showed radiographic evidence of 1 mm polyethylene wear. Radiographic review showed no evidence of osteolysis or stem subsidence. Harris Hip Scores improved from a mean of 68.8 (range 58-87) preoperatively to 98.9 (range 65-100) at final clinical assessment. This constrained acetabular prosthesis had a dislocation rate of less than 2%, with 0% component failure rate at a minimum of 2 years of follow-up suggesting this prosthesis may be a viable alternative for patients at risk for instability or those known to have recurrent instability.
منابع مشابه
Long Term Outcomes of Total Hip Arthroplasty in Young Patients under 30
Background: We aimed to report outcomes of total hip arthroplasty (THA) in very young patients under the year of 30. Methods: Thirty patients (45 hips) with various indications for THA were retrospectively reviewed radiologically and clinically and analyzed regarding survival, reasons of failure, factors associated with outcomes and postoperative complications. Results: Within a mean fol...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملOmnifit acetabular component: a solution to preventing and treating dislocation.
PURPOSE To assess short- to medium-term outcome of the Omnifit constrained acetabular component in preventing dislocation in at-risk patients after total hip arthroplasty (THA). METHODS 81 patients (mean age, 77 years) underwent either primary or revision THA with an Omnifit constrained acetabular component and were followed up clinically and radiologically for a mean period of 24 months. R...
متن کاملPartial 2-Stage Revision in Chronic Hip Arthroplasty Infections: A Review
Background: Periprosthetic hip infections (PHIs) are troublesome complications of hip arthroplasties. The gold standard procedure for treating chronic PHI is a 2-stage approach. Recently, however, more conservative approaches have been developed to spare the osseointegrated components and avoid sequestra, bone loss, devascularization, and difficult reconstructions. The partial ...
متن کاملCement-in-cement acetabular revision with a constrained tripolar component.
Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2015