The Use of an Automated, Portable Glucose Control System for Overnight Glucose Control in Adolescents and Young Adults With Type 1 Diabetes

نویسندگان

  • Michael J. O'Grady
  • Adam J. Retterath
  • D. Barry Keenan
  • Natalie Kurtz
  • Martin Cantwell
  • Glenn Spital
  • Michael N. Kremliovsky
  • Anirban Roy
  • Elizabeth A. Davis
  • Timothy W. Jones
  • Trang T. Ly
چکیده

OBJECTIVE A key milestone in progress towards providing an efficacious and safe closed-loop artificial pancreas system for outpatient use is the development of fully automated, portable devices with fault detection capabilities to ensure patient safety. The ability to remotely monitor the operation of the closed-loop system would facilitate future physician-supervised home studies. RESEARCH DESIGN AND METHODS This study was designed to investigate the efficacy and safety of a fully automated, portable, closed-loop system. The Medtronic Portable Glucose Control System (PGCS) consists of two subcutaneous glucose sensors, a control algorithm based on proportional-integral-derivative with insulin feedback operating from a BlackBerry Storm smartphone platform, Bluetooth radiofrequency translator, and an off-the-shelf Medtronic Paradigm Veo insulin pump. Participants with type 1 diabetes using insulin pump therapy underwent two consecutive nights of in-clinic, overnight, closed-loop control after a baseline open-loop assessment. RESULTS Eight participants attended for 16 overnight studies. The PGCS maintained mean overnight plasma glucose levels of 6.4 ± 1.7 mmol/L (115 ± 31 mg/dL). The proportion of time with venous plasma glucose <3.9, between 3.9 and 8 (70 and 144 mg/dL), and >8 mmol/L was 7, 78, and 15%, respectively. The proportion of time the sensor glucose values were maintained between 3.9 and 8 mmol/L was greater for closed-loop than open-loop (84.5 vs. 46.7%; P < 0.0001), and time spent <3.3 mmol/L was also reduced (0.9 vs. 3%; P < 0.0001). CONCLUSIONS These results suggest that the PGCS, an automated closed-loop device, is safe and effective in achieving overnight glucose control in patients with type 1 diabetes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unsupervised home use of an overnight closed-loop system over 3–4 weeks: a pooled analysis of randomized controlled studies in adults and adolescents with type 1 diabetes

AIMS To compare overnight closed-loop and sensor-augmented pump therapy in patients with type 1 diabetes by combining data collected during free-living unsupervised randomized crossover home studies. METHODS A total of 40 participants with type 1 diabetes, of whom 24 were adults [mean ± standard deviation (s.d.) age 43 ± 12 years and glycated haemoglobin (HbA1c) 8.0 ± 0.9%] and 16 were adoles...

متن کامل

EFFECTIVENESS OF INSTRUCT COGNITIVE ERRORS IN THE WAY OF PHILOSOPHY FOR CHILDREN AND ADOLESCENTS, IN COGNITIVE ERRORS, WELL-BEING AND BLOOD SUGAR LEVELS OF CHILDREN AND ADOLESCENTS WITH TYPE I DIABETES

Background: Type 1 diabetes is a chronic disease that children and adolescents do not have the ability to care for themselves, despite having enough information about their self-care (nutrition, insulin, exercise, etc.). Self-care, such as any behavior, can be influenced by the way of thinking, and the philosophy teaching method can be a suitable educational tool for changing thinking. The purp...

متن کامل

Overnight Glucose Control With an Automated, Unified Safety System in Children and Adolescents With Type 1 Diabetes at Diabetes Camp

OBJECTIVE To determine the safety and efficacy of an automated unified safety system (USS) in providing overnight closed-loop (OCL) control in children and adolescents with type 1 diabetes attending diabetes summer camps. RESEARCH DESIGN AND METHODS The Diabetes Assistant (DIAS) USS used the Dexcom G4 Platinum glucose sensor (Dexcom) and t:slim insulin pump (Tandem Diabetes Care). An initial ...

متن کامل

The detection of salivary glucose, caries and periodontal status in diabetes ‎mellitus patients

OBJECTIVE: Oral manifestations in diabetic patients can have different causes. Possibly, one of these causes is salivary glucose. The aim of this study was to evaluate salivary glucose concentrations in patients with Type II diabetes mellitus (DM) and their association with oral and dental manifestations and compare them with normal adults. MATERIALS AND METHODS: In this analytical study, 128 p...

متن کامل

Designing a glycemic control strategy to maintain glucose homeostasis and prevent hypoglycemia for subjects with type 1 diabetes

This paper presents using the fractional PImDn controller module which manipulates insulin infusion rate to maintain normoglycemia in subjects with type 1 diabetes. To prevent severe hypoglycemia, a conventional proportional controller is used to regulate glucagon infusion rate when the blood glucose levels fall below a threshold. Two sets of controller parameters are obtained and evaluated. Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2012