Development of Series Elastic Actuators for Impedance Control of an Active Ankle Foot Orthosis

نویسنده

  • Bruno Jardim
چکیده

This paper deals with force and impedance control of series elastic actuators for driving the joints of an exoskeleton for lower limbs. Series elastic actuators are devices where elastic components are introduced between the motor’s output and the load. From the deflection of these components, it is possible to measure the force applied to the load and to control it. Also, the mechanical impedance of the actuator/load interface can be regulated to the typical values of joint’s stiffness and damping presented by humans during the walking. Results of force and impedance control applied to an active ankle-foot orthosis driven by a series elastic actuator are presented. Also, a variable impedance control strategy is performed to reproduce the behavior of an actual ankle joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Evaluation of an Articulated Ankle Foot Orthosis with Plantarflexion Resistance on the Gait: a Case Series of 2 Patients with Hemiplegia

Ankle-foot orthoses (AFOs) have been described to have positive effects on the gait biomechanics in stroke patients. The plantarflexion resistance of an AFO is considered important for hemiplegic patients, but the evidence is still limited. The purpose of this case series was to design and evaluate the immediate effect of an articulated AFO on kinematics and kinetics of lower-limb joints in str...

متن کامل

Retractable Prosthesis for Transfemoral Amputees Using Series Elastic Actuators and Force Control

We present a highly functional and cost-effective prosthesis for transfemoral amputees that uses series elastic actuators. These actuators allow for accurate force control, low impedance and large dynamic range. The design involves one active joint at the knee and a passive joint at the ankle. Additionally, the socket was designed using mirroring of compliances to ensure maximum comfort.

متن کامل

Patient-Adaptive Prosthetic and Orthotic Leg Systems

Two computer-controlled devices for leg rehabilitation are presented: 1) an external knee prosthesis for trans-femoral amputees; and 2) a force-controllable ankle-foot orthosis to assist individuals suffering from drop-foot, a gait pathology resulting from muscle weakness in ankle dorsiflexors. Here muscle-like actuators and biologically-inspired control schemes are employed to enhance patient ...

متن کامل

Clutchable Series Elastic Actuator for a Gait-Assistive Active Orthosis for Subjects with SCI

A spinal cord injury (SCI) disrupts the motor and sensory functions of the nervous system, limitingmotion capabilities and reducing the quality of life of affected people. An active stance-control knee-ankle-foot orthosis was developed and tested to aid incomplete SCI subjects by increasing theirmobility and independence [1]. A further improvement of the orthosis is conducted by...

متن کامل

Neuromechanical adaptation to hopping with an elastic ankle-foot orthosis.

When humans hop or run on different surfaces, they adjust their effective leg stiffness to offset changes in surface stiffness. As a result, the overall stiffness of the leg-surface series combination remains independent of surface stiffness. The purpose of this study was to determine whether humans make a similar adjustment when springs are placed in parallel with the leg via a lower limb orth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009