Maternal-fetal in vivo imaging: a combined PET and MRI study.

نویسندگان

  • Helene Benveniste
  • Joanna S Fowler
  • William D Rooney
  • Daryn H Moller
  • W Walter Backus
  • Donald A Warner
  • Pauline Carter
  • Payton King
  • Bruce Scharf
  • David A Alexoff
  • Yeming Ma
  • Paul Vaska
  • David Schlyer
  • Nora D Volkow
چکیده

UNLABELLED An understanding of how drugs are transferred between mother and fetus during the gestational period is an important medical issue of relevance to both therapeutic drugs and drugs of abuse. Though there are several in vitro and in vivo methods to examine this issue, all have limitations. Furthermore, ethical and safety considerations generally preclude such studies in pregnant humans. PET and appropriately labeled compounds have the ability to provide information on both maternal-fetal drug pharmacokinetics and pharmacodynamics. We present here a nonhuman primate animal model and the methodology for combining PET and MRI to identify fetal organs and to measure maternal and fetal isotope distribution using (18)F-FDG and a whole-body imaging protocol to demonstrate proof-of-principle. METHODS One nonpregnant nonhuman primate was used for determination of the anesthesia protocol and MRI methods and 3 pregnant nonhuman primates (Macaques radiata) weighing 4.5-7 kg were used for the imaging study and anesthetized with propofol (160-300 micro g/kg/min). Anatomic T2-weighted MR images were acquired on a 4-T MR instrument. Subsequently, whole-body PET images were acquired 35 min after injection of (18)F-FDG, and standardized uptake values (SUVs) were calculated. Image processing and coregistration were performed using commercial software. RESULTS All animals underwent uneventful general anesthesia for a period of up to 7 h. Coregistration of PET and MR images allowed identification of fetal organs and demonstrated that (18)F-FDG readily crosses the placenta and that (18)F accumulates in both maternal and fetal brain, heart, and bladder. Brain SUVs averaged 1.95 +/- 0.08 (mean +/- SD) and 1.58 +/- 0.11 for mothers and fetuses, respectively. Monkeys delivered healthy babies after a normal gestational term of 170 d following the PET/MRI study. CONCLUSION The pregnant macaque in combination with PET and MRI technology allows the measurement of radioisotope distribution in maternal and fetal organs. This demonstrates the potential for noninvasively measuring the transfer of drugs across the placenta and for measuring the fetal drug distribution. It also opens up the possibility for studying binding and elimination as well as the effects of a drug on specific cellular elements and physiologic processes during the gestational period in a primate model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

Estimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom

One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

Noninvasive Stem Cell Labeling Using USPIO Technique and their Detection with MRI

Background: To date, several imaging techniques to track stem cells are used such as positron emission tomography (PET), single photon emission computed tomography (SPECT), Bioluminescence imaging (BLI), fluorescence imaging, CT scan and magnetic resonance imaging (MRI). Although, overall sensitivity of MRI compared to SPECT and Bioluminescence techniques are lower, but due to high spatial reso...

متن کامل

Detection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey

Objective(s): The aim of this study was to analyze detection rates and effectiveness of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 44 9  شماره 

صفحات  -

تاریخ انتشار 2003