A colorimetric method for the determination of carboxyhaemoglobin over a wide range of concentrations.
نویسندگان
چکیده
A colorimetric technique for the determination of carboxyhaemoglobin in blood is described. Carbon monoxide released from blood in a standard Conway unit reacts with palladous chloride/arsenomolybdate solution to produce a blue colour. Using 0.5 to 2 ml. of blood, the method will estimate carboxyhaemoglobin accurately at levels from 0.1% to 100% of total haemoglobin and in the presence of other abnormal pigments.A number of methods are available for the determination of carboxyhaemoglobin; none is accurate below a concentration of 1.5 g. carboxyhaemoglobin per 100 ml. but for most clinical purposes this is not important. For forensic purposes and occasionally in clinical use, an accurate determination of carboxyhaemoglobin below 750 mg. per 100 ml. may be required and no really satisfactory method is at present available. Some time ago when it was important to know whether a person who was found dead in a burning house had died before or after the fire had started, we became interested in developing a method which would determine accurately carboxyhaemoglobin at levels of 750 mg. per 100 ml.
منابع مشابه
Chitosan Capped Silver Nanoparticles as Colorimetric Sensor for the Determination of Iron(III)
A selective, simple and low-cost method for the colorimetric determination of Fe3+ ions based on chitosan capped silver nanoparticles (Chit-AgNPs) was presented. Chitosan is a cationic polyelectrolyte and possesses amino and hydroxy groups which make it widely used as a capping agent for Ag NPs. The synthesized chitosan capped silver nanoparticles with excellent colloidal stability were charact...
متن کاملDye Concentrations Determination in Ternary Mixture Solution by Using Colorimetric Algorithm
This publication uses a colorimetric method based on the absorbance spectra of dye solutions to improve on Beer’s law when calculating the dye concentrations of a three-component mixture. The performance of the new method is compared with that of Beer’s law evaluated at three wavelengths, and Beer’s law evaluated at 16 wavelengths. Colorimetric method gives the best prediction of d...
متن کاملIon-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method
2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...
متن کاملExtraction - Spectrophotometric Determination of Palladium with Tetrabutyl Ammonium Iodide
A sensitive and selective extraction - spectrophotometric method for the determination of trace amounts of palladium is reported. The method is based on quantitative extraction of brownish tetrabutylammoium tetraiodopalladium (II) ion pair into a small valume of chloroform at pH 1.3-12.0, followed by spectrophotometric measurements. The Beer's law is obeyed over the range 0.02-1.09 <em...
متن کاملNew Enzymatic Colorimetric Method for the Quantitative Determination of Phenylalanine in Dry-Blood Spots
Phenylketonuria (PKU) is an autosomal recessive disorder, which is characterized by severe mental retardation, microcephaly and seizures. The symptoms of this disease can be prevented if detected soon after birth. Therefore, blood Phenylalanine (Phe) measurement is essential for the early diagnosis, treatment and dietary monitoring of PKU patients. The goal of this research was to introduce a r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical pathology
دوره 15 شماره
صفحات -
تاریخ انتشار 1962