NANO-SECOND TIME-RESOLVED SYNCHROTRON X-RAY DIFFRACTION STUDY OF OLIVINE UNDER LASER-INDUCED SHOCK COMPRESSION. T. Mikouchi
نویسندگان
چکیده
UNDER LASER-INDUCED SHOCK COMPRESSION. T. Mikouchi 1 , K. Ohsumi 2 , K. Ichiyanagi 3 , S. Adachi 3,4 , S. Nozawa 3 , S. Koshihara 3,5 , and M. Zolensky 2 , 1 Dept. of Earth and Planet. Sci., Univ. of Tokyo, Hongo, Tokyo 1130033, Japan, 2 KT, NASA-JSC, Houston, TX 77058, USA, 3 ERATO, Japan Sci. and Tech. Agency, Tsukuba, Ibaraki 305-0801, Japan, 4 High Energy Accelerator Res. Org. (KEK), Oho, Tsukuba, Ibaraki 305-0801, Japan, 5 Frontier Res. Center, Tokyo Inst. Tech., Oh-okayama, Tokyo 152-8551, Japan (E-mail: [email protected]).
منابع مشابه
Structural Dynamics of Materials under Shock Compression Investigated with Synchrotron Radiation
Characterizing material dynamics in non-equilibrium states is a current challenge in material and physical sciences. Combining laser and X-ray pulse sources enables the material dynamics in non-equilibrium conditions to be directly monitored. In this article, we review our nanosecond time-resolved X-ray diffraction studies with 100-ps X-ray pulses from synchrotron radiation concerning the dynam...
متن کاملFe-Ni METAL AND MAGNETITE NANO-PARTICLES IN “BROWN” COLOR OLIVINES FROM MARTIAN
Introduction: Recent TEM studies revealed that Fe-Ni metal nano-particles are responsible for the dark “brown” color of olivine in the NWA2737 chassignite, which is interpreted to have formed by reduction of olivine due to heavy shock events [1,2]. Color change of olivine is important to understand the remote sensing data as is the case for space weathering [3,4]. Furthermore, nano-phase Fe par...
متن کاملSpatially Resolved Characterization of Residual Stress Induced by Micro Scale Laser Shock Peening(1501)
Single crystal Aluminum of (001) orientation were shock peened using laser beam of 12 micron diameter and observed with X-ray micro-diffraction techniques based on a synchrotron light source. The X-ray micro-diffraction affords micron level resolution as compared with conventional X-ray diffraction which has only mm level resolution. The asymmetric and broadened diffraction profiles registered ...
متن کاملSpatially Resolved Characterization of Residual Stress Induced by Micro Scale Laser Shock Peening
Single crystal aluminum and copper of (001) and (110) orientation were shock peened using laser beam of 12 micron diameter and observed with X-ray micro-diffraction techniques based on a synchrotron light source. The X-ray micro-diffraction affords micron level resolution as compared with conventional X-ray diffraction which has only mm level resolution. The asymmetric and broadened diffraction...
متن کاملTime-resolved x-ray diffraction study of laser-induced shock and acoustic waves in single crystalline silicon
waves in single crystalline silicon K.-D. Liss, T. d’Almeida, M. Kaiser, R. Hock, A. Magerl, and J. F. Eloy The Bragg Institute, Australian Nuclear Science and Technology Organisation, Private Mail Bag 1, Menai, New South Wales 2234, Australia Department of Physics, Cavendish Laboratory, University of Cambridge, J. J. Thomson Avenue, Cambridge CB3 0HE, United Kingdom Swiss Light Source, Paul-Sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009