A Comparison of Magnetic Resonance Angiography Techniques for the Evaluation of Intracranial Aneurysms Treated With Stent-assisted Coil Embolization

نویسندگان

  • Krishnamoorthy Thamburaj
  • Kevin Cockroft
  • Amit K Agarwal
  • Shyam Sabat
  • Paul Kalapos
چکیده

AIM To identify the effective magnetic resonance angiography (MRA) technique to monitor intracranial aneurysms treated with stent-assisted coiling. MATERIALS AND METHODS Retrospective analysis of various MRA techniques was performed in 42 patients. Three neuroradiologists independently compared non-contrast time of flight (ncTOF) MRA of the head, contrast-enhanced time of flight (cTOF) MRA of the head and dynamic contrast-enhanced MRA (CEMRA) of the head and neck or of the head. Digital subtraction angiography (DSA) was available for comparison in 32 cases. Inter-rater agreement (kappa statistic) was assessed. RESULTS Artifactual in-stent severe stenosis or flow gap was identified by ncTOF MRA in 23 of 42 cases (55%) and by cTOF MRA in 23 of 38 cases (60%). DSA excluded in-stent stenosis or occlusion in all 32 cases. No difference was noted between ncTOF and cTOF in the demonstration of neck remnants or residual aneurysms in three cases each. CEMRA of the head and neck or of the head was rated superior to ncTOF and cTOF MRA by all three investigators in seven out of eight cases. In one case, all three techniques demonstrated signifcant artifacts due to double stent placement during coiling. The kappa statistic revealed 0.8 agreement between investigators. CONCLUSIONS In the assessment of stent-assisted coiling of intracranial aneurysm, both ncTOF and cTOF MRA show similar results. CEMRA tends to show better flow signals in stent and residual aneurysm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing Blood Flow in an Intracranial Stent: A Feasibility Study of MR Angiography Using a Silent Scan after Stent-Assisted Coil Embolization for Anterior Circulation Aneurysms.

BACKGROUND AND PURPOSE Blood flow in an intracranial stent cannot be visualized with 3D time-of-flight MR angiography owing to magnetic susceptibility and radiofrequency shielding. As a novel follow-up tool after stent-assisted coil embolization, we applied MRA by using a Silent Scan algorithm that contains an ultrashort TE combined with an arterial spin-labeling technique (Silent MRA). The pur...

متن کامل

Superior hypophyseal artery aneurysms have the lowest recurrence rate with endovascular therapy.

BACKGROUND AND PURPOSE Given the challenges posed by surgical clipping, endovascular techniques have been increasingly used to treat SHA aneurysms. The purpose of this study was to assess the safety and efficacy of endovascular techniques in the treatment of SHA aneurysms. MATERIALS AND METHODS Medical charts and initial and follow-up angiograms were reviewed retrospectively for all patients ...

متن کامل

Clinical and Angiographic Outcomes of Wide-necked Aneurysms Treated with the Solitaire AB Stent

OBJECTIVE This study investigated the clinical and angiographic outcomes of treatment with stent-assisted coil embolization using the Solitaire AB stents for wide-necked intracranial aneurysms. METHODS From October 2010 to December 2011, 22 patients with aneurysms were treated with the Solitaire AB stent. One patient with a dissecting aneurysm was excluded, thus 21 patients with 21 wide-necke...

متن کامل

Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images

OBJECTIVE The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms with the Enterprise stent. MATERIALS AND METHODS Two experienced neurointerventionists independently reviewed the follow-up MRA studies of 40 consecutive patients with 44 coiled aneu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016