Current Regulator Instabilities on Parallel Voltage Source Inverters

نویسندگان

  • J. Thunes
  • R. Kerkman
  • D. Schlegel
  • T. Rowan
چکیده

Parallel inverters are often used to meet system power requirements beyond the capacity of the largest single structure. They have also been used to reduce harmonics, reduce PWM switching frequency and increase available output voltage or frequency. The type of parallel structure depends on the construction of the load motor, the most prevalent are dual three phase machines, split-phase machines, six phase machines, and a standard three phase machine with interphase reactors. Operation of parallel structures presents areas for investigation encompassing analysis, simulation, control, and design. The paper reports on the commissioning of a 775 hp dual winding three phase motor with parallel inverters. A simple method of paralleling structures with carrier based PWM current regulators (CRPWM) to independently regulate each inverter’s current is employed. Experimental results show a loss of current control that is similar to a random event. The instability between the parallel inverters and the common motor can result in large uncontrolled currents. Simulations established the reduction in controller gain, as the regulator enters the PWM pulse dropping or overmodulation region, results in a loss of current control. Experimental results show the loss of current control is the result of an interaction between the parallel inverters through the dual wound three phase motor. Modifications were made to the modulator and a two phase discontinuous controller employed; the gain characteristic of the two phase modulator in the overmodulation region extends the dynamic range of the motor drive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Compensation of Electrical Power Systems Using Multilevel Voltage Source Inverter

A New Static Var Generator (SVG), using cascaded full-bridge inverters (FBI) with binary output levels and the parallel connections of two cascaded inverters by means of current sharing reactor in each phases is introduced. The new M-level inverter, where M is 2n+2 - 3, consists of only 2n single-phase full bridges for each phases. The proposed technique not only increases the current capacity ...

متن کامل

Harmonic Reduction Technique Using Flying Capacitor Based Z Source Inverter for a DVR

The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...

متن کامل

Load Sharing Control of Parallel Inverters with Uncertainty in the Output Filter Impedances for Islanding Operation of AC Micro-Grid

Parallel connection of inverter modules is a solution to increase reliability, efficiency and redundancy of inverters in Micro-Grid system. Proper load sharing among parallel inverters is a key point. The circulating current among the inverters can greatly reduce the efficiency or even cause instability of the system. In this paper, a control strategy for improving the load sharing performance ...

متن کامل

DSP Control of Current Sourcing Inverters

Grid connected inverters are important building blocks in renewable energy conversion systems. In conventional voltage sourcing grid connected inverters, any mismatch between the synthesized output waveforms of the inverters and the grid voltage will generate large erroneous currents unless a fast current feedback is used. The current control requires rather fast sampling rates and considerable...

متن کامل

Introduction and Analysis of a Novel Quasi - Series Resonant DC Link

Soft Switcing techniques have recently been applied in the design of dc-ac converters, in order to achive better performance, higher efficiency, and power density. One of the soft switching techniques uesd in inverters is resonant dc links. These topologies have some disadvantages such as irregular current peaks, large voltage peaks, uncotrollble pulse width, etc. Another soft switching method ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997