Repeatability of Foveal Measurements Using Spectralis Optical Coherence Tomography Segmentation Software

نویسندگان

  • Irene Ctori
  • Byki Huntjens
  • Knut Stieger
چکیده

PURPOSE To investigate repeatability and reproducibility of thickness of eight individual retinal layers at axial and lateral foveal locations, as well as foveal width, measured from Spectralis spectral domain optical coherence tomography (SD-OCT) scans using newly available retinal layer segmentation software. METHODS High-resolution SD-OCT scans were acquired for 40 eyes of 40 young healthy volunteers. Two scans were obtained in a single visit for each participant. Using new Spectralis segmentation software, two investigators independently obtained thickness of each of eight individual retinal layers at 0°, 2° and 5° eccentricities nasal and temporal to foveal centre, as well as foveal width measurements. Bland-Altman Coefficient of Repeatability (CoR) was calculated for inter-investigator and inter-scan agreement of all retinal measurements. Spearman's ρ indicated correlation of manually located central retinal thickness (RT0) with automated minimum foveal thickness (MFT) measurements. In addition, we investigated nasal-temporal symmetry of individual retinal layer thickness within the foveal pit. RESULTS Inter-scan CoR values ranged from 3.1 μm for axial retinal nerve fibre layer thickness to 15.0 μm for the ganglion cell layer at 5° eccentricity. Mean foveal width was 2550 μm ± 322 μm with a CoR of 13 μm for inter-investigator and 40 μm for inter-scan agreement. Correlation of RT0 and MFT was very good (ρ = 0.97, P < 0.0005). There were no significant differences in thickness of any individual retinal layers at 2° nasal compared to temporal to fovea (P > 0.05); however this symmetry could not be found at 5° eccentricity. CONCLUSIONS We demonstrate excellent repeatability and reproducibility of each of eight individual retinal layer thickness measurements within the fovea as well as foveal width using Spectralis SD-OCT segmentation software in a young, healthy cohort. Thickness of all individual retinal layers were symmetrical at 2°, but not at 5° eccentricity away from the fovea.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the Accuracy of Foveal Avascular Zone Measurements Using Optical Coherence Tomography Angiography: Segmentation and Scaling

PURPOSE The foveal avascular zone (FAZ) is altered in numerous diseases. We assessed factors (axial length, segmentation method, age, sex) impacting FAZ measurements from optical coherence tomography (OCT) angiography images. METHODS We recruited 116 Caucasian subjects without ocular disease, and acquired two 3 × 3 mm AngioVue scans per each right eye (232 total scans). In images of the super...

متن کامل

Identifying the boundaries of retinal pigment epithelial detachments using two spectral-domain optical coherence tomography instruments.

BACKGROUND AND OBJECTIVE To compare two spectral-domain optical coherence tomography (SD-OCT) instruments in identifying the boundaries of retinal pigment epithelium detachment (PED). PATIENTS AND METHODS 27 eyes were scanned with Cirrus and Spectralis SD-OCT instruments during a single visit. Two Cirrus scan patterns were used: the 512 × 128 and 200 × 200 covering a 6 × 6 mm (20° × 20°) area...

متن کامل

Platform-Independent Cirrus and Spectralis Thickness Measurements in Eyes with Diabetic Macular Edema Using Fully Automated Software

PURPOSE We determine whether the automated segmentation software, Duke Optical Coherence Tomography Retinal Analysis Program (DOCTRAP), can measure, in a platform-independent manner, retinal thickness on Cirrus and Spectralis spectral domain optical coherence tomography (SD-OCT) images in eyes with diabetic macular edema (DME) under treatment in a clinical trial. METHODS Automatic segmentatio...

متن کامل

Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion

Purpose. To evaluate macular thickness, agreement, and intraclass repeatability in three optical coherence tomography (OCT) devices: the time domain (TD) Stratus OCT and two spectral domain (SD) OCTs, Spectralis and Cirrus SD-OCT, in eyes with macular edema secondary to diabetic retinopathy (DR) and retinal vein occlusion (VO). Methods. In a prospective observational study at a university-based...

متن کامل

Foveal Thickness between Stratus and Spectralis Optical Coherence Tomography in Retinal Diseases

PURPOSE To compare the foveal thickness (FT) parameters measured by Stratus optical coherence tomography (OCT) and Spectralis OCT in various retinal diseases and to construct conversion formulas between the two types of OCT devices. METHODS We examined 366 consecutive patients (475 eyes) with retinal diseases and 13 normal controls (13 eyes). The patients were categorized into eight retinal d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015