Mid-term survivorship of cruciate-retaining versus posterior-stabilized total knee arthroplasty using modular mini-keel tibial implants
نویسندگان
چکیده
BACKGROUND Reports of diverse outcomes in modular mini-keel tibial componentry for total knee arthroplasty (TKA) have raised concerns about early aseptic loosening. Cruciate-retaining (CR) prostheses, using mini-keel implants, have yet to be reported and compared to posterior-stabilizing (PS) designs. METHODS A retrospective, case-matched study of 91 consecutive TKAs (n = 46 CR; n = 45 PS prostheses), using modular mini-keel tibial componentry with a 45-mm drop down stem extension, was conducted. The Knee Society Score functional survey, radiographic analysis including alignment and periprosthetic radiolucency, TKA prosthesis longevity, and surgical complications were reported and compared between CR and PS groups. RESULTS The Knee Society Score at 5-year follow-up averaged 81.67 ± 11.97 and 80.12 ± 14.16 in the CR and PS groups, respectively (p = 0.29). The femorotibial angle averaged 5.85° ± 2.62° and 5.85° ± 3.27° valgus in the CR and PS groups, respectively (p = 0.60). The average tibial component angle was 0.46° ± 1.6° and 0.61° ± 1.3° varus in the CR and PS groups, respectively (p = 0.30); posterior inclination averaged 2.28° ± 2.36° and 1.93° ± 2.72° in the CR and PS groups, respectively (p = 0.51). Radiolucency was noted in 17 zones of the CR group and in 9 zones of the PS group (p = 0.24). Three TKAs required further surgery: one locking plate fixation for a periprosthetic tibial fracture (PS group) and two revision TKAs (one CR infection and one PS fracture). CONCLUSION Modular mini-keel tibial components showed good reliability and results with both CR and PS prostheses in minimally invasive surgery TKA.
منابع مشابه
Minimum 5-year Follow-up Results of Minimally Invasive Total Knee Arthroplasty Using Mini-Keel Modular Tibial Implant
PURPOSE To evaluate the minimum 5-year mid-term clinical and radiological results of minimally invasive surgery total knee arthroplasty (MIS-TKA) using a mini-keel modular tibia component. MATERIALS AND METHODS We retrospectively evaluated 254 patients (361 cases) who underwent MIS-TKA between 2005 and 2006. The latest clinical and radiological assessments were done in 168 cases that had been...
متن کاملRationale of Cruciate Retaining Design in Rheumatoid Arthritis: A Review of Clinical Analysis and its Role in Rheumatoid Arthritis
Background Over the years, proponents of total knee designs (cruciate retaining and posterior stabilised) have conducted several long-term studies to claim the potential of these designs in several subsets of patients. Total knee arthroplasty (TKA) in patients with rheumatoid arthritis has also been one such domain where numerous studies were conducted in the past. A general perception among ma...
متن کاملBiomechanical Consequences of Anterior Femoral Notching in Cruciate-Retaining Versus Posterior-Stabilized Total Knee Arthroplasty.
Anterior femoral notching during total knee arthroplasty is a potential risk factor for periprosthetic supracondylar femur fracture. We conducted a study to determine if the design of the femoral implant changes the risk for periprosthetic supracondylar femur fractures after anterior cortical notching. An anterior cortical defect was created in 12 femoral polyurethane models. Six femora were in...
متن کاملPosterior cruciate-retaining, rotating-platform total knee arthroplasty: minimum 4-year follow-up study.
Rotating-platform, mobile-bearing total knee arthroplasty was initially developed using a posterior cruciate-sacrificing technique and design. Posterior cruciate-substituting and -retaining, rotating-platform total knee arthroplasty designs were developed later. The purpose of this study was to evaluate a minimum 4-year follow-up of total knee arthroplasty performed with a posterior cruciate-re...
متن کاملEffects of Tibial Insert Slope on Polyethylene Wear and Stress
INTRODUCTION: Both posterior stabilized (PS) and cruciate retaining (CR) total knee replacement systems have demonstrated high rates of survivorship, high clinical knee scores and high patient satisfaction scores for decades. However, CR total knees sometimes exhibit more varied kinematics and a smaller range of motion than similar PS knees. Many factors can cause this, but one important factor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2018