Variations in the flow of cerebrospinal fluid through spinal needles.
نویسندگان
چکیده
The dimensions of currently available spinal needles (0.7 mm (22-gauge) to 0.45 mm (26-gauge) external diameter) were measured and compared with the International Standard (ISO 7864-1984 E). The in vitro performance of the needles was assessed by comparing times to appearance of cerebrospinal fluid and flow rates through the needles. There were wide variations in the measurements and performance of the different needles.
منابع مشابه
Cerebrospinal Fluid and Spinal Anesthesia Parameters in Healthy Versus Opium-Addict Patients during Lower Limb Surgery
متن کامل
مدلسازی عددی هیپوترمی مغزی با استفاده از سرد کردن مایع مغزی-نخاعی
Background: Brain hypothermia by reducing the temperature of the cerebrospinal fluid is done by a cooling pad in the thoracic region and protect brain from the ischemic injuries. Along with the spinal cord, the brain is an essential partner in the central nervous system, and similarly, it is surrounded and protected from the bony skull and from shock by cerebrospinal fluid. The brain analyzes i...
متن کاملDiagnostic and therapeutic lumbar puncture performed safely and efficiently with a thin blunt needle.
INTRODUCTION The risk of postdural puncture headache following lumbar puncture can be reduced by choosing a blunt spinal needle or by using a smaller needle diameter. Reports indicate that lumbar puncture practiced outside of the anaesthetic discipline does not adhere to the current level of evidence. To examine the practice among haematologists in Denmark, we performed a national survey. In ad...
متن کاملQuantitative assessment of physiological cerebrospinal fluid flow in the cervical spinal canal with 3.0T phase-contrast cine MRI☆
A total of 50 healthy volunteers aged between 18 and 54 years underwent phase-contrast cine MRI to assess cerebrospinal fluid flow characteristics in different regions of the vertebral canal. The results revealed that the cerebrospinal fluid peak flow velocity and peak flow rate in the systolic phase were significantly greater than those in the diastolic phase at the same level in the subarachn...
متن کاملInvestigation of Cerebrospinal Fluid Flow Characteristics Through Adult and Pediatric Shunt Tubing
Shunt malfunction in adult and pediatric populations continues to be a perplexing problem. We examined artificial cerebrospinal fluid flow differential between adult and pediatric shunt systems. Flow through adult and pediatric-sized catheters was compared with artificial CSF using shunt systems containing new catheters, explanted catheters, 2-piece catheters, 3-piece catheters and with varying...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 59 11 شماره
صفحات -
تاریخ انتشار 1987