Successful reversal of immediate paraplegia associated with repair of acute Type A aortic dissection using cerebrospinal fluid drainage.
نویسندگان
چکیده
We present a case of a 49-year old man who suffered from immediate paraplegia upon awakening from anaesthesia after surgery for acute aortic dissection Type A. A catheter was promptly inserted into the spinal canal for cerebrospinal fluid drainage, and the cerebrospinal fluid pressure was maintained <10 cmH2O. Although magnetic resonance imaging showed extensive spinal cord ischaemia, the patient gradually recovered from the paraplegia and was able to walk by himself after rehabilitation. In some cases, cerebrospinal fluid drainage can be effective for the treatment of immediate postoperative spinal cord damage.
منابع مشابه
Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report
Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...
متن کاملA case of effective cerebrospinal fluid drainage for paraplegia caused by acute aortic dissection.
A 65-year-old man with sudden back pain was transferred to our hospital by ambulance, who also complained of sensory and motor disorder of bilateral legs on arrival. The neurological disorder was gradually aggravated and paraplegia below the level of Th10 was manifested. Computed tomography demonstrated DeBakey IIIb acute aortic dissection; therefore, the paraplegia was thought to be due to spi...
متن کاملSpinal cord ischemia after elective stent-graft repair of the thoracic aorta.
OBJECTIVES Neurologic deficit after endovascular treatment of the thoracic aorta is a complication reported with variable frequency that may be associated with severe morbidity and mortality. The mechanism of spinal cord ischemia appears to be multifactorial and remains ill-defined. We reviewed our experience to investigate the determinants of paraplegia after stent-graft repair of the thoracic...
متن کاملLate cerebrospinal fluid drainage for paraplegia developed following Bentall procedure for acute type a aortic dissection
Methods A 51 year old woman who had chest and back pain and syncope, was admitted to emergency department. Thorax CT revealed acute type A aortic dissection and she underwent emergency surgery. Modified Bentall procedure along with hemiarch replacement was performed using antegrade selective cerebral perfusion. The next day she developed cardiac tamponade and ischemia of the left leg. Re-explor...
متن کاملParaplegia following elective endovascular repair of abdominal aortic aneurysm: reversal with cerebrospinal fluid drainage.
Paraplegia secondary to spinal cord ischaemia is a rare but devastating complication of abdominal aortic aneurysm repair. We report a case of paraplegia following elective endovascular repair of an infrarenal aortic aneurysm. A cerebrospinal fluid (CSF) drain was immediately inserted and resulted in full neurological recovery. This case highlights the fact that endovascular techniques are prone...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 17 6 شماره
صفحات -
تاریخ انتشار 2013