Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013

نویسندگان

  • Shu-Ping Lin
  • Wen-Ye Lin
  • Jung-Tzu Chang
  • Chun-Feng Chu
چکیده

Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3-5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comment on “System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System”

Use of blood glucose (BG) meters in the self-monitoring of blood glucose (SMBG) significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO) ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe,...

متن کامل

ISO‐Based Assessment of Accuracy and Precision of Glucose Meters in Dogs

BACKGROUND Portable blood glucose meters (PBGMs) allow easy glucose measurements. As animal-specific PBGMs are not available everywhere, those for humans are widely used. OBJECTIVES To assess the accuracy and precision of 9 PBGMs in canine whole blood (WB) and plasma, based on the ISO 15197:2013. ANIMALS Fifty-nine client-owned dogs attending the Veterinary Teaching Hospital. METHODS Anal...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197.

BACKGROUND Accurate and reliable blood glucose (BG) measurements require that different test strip lots of the same BG monitoring system provide comparable measurement results. Only a small number of studies addressing this question have been published. METHODS In this study, four test strip lots for each of five different BG systems [Accu-Chek® Aviva (system A), FreeStyle Lite® (system B), G...

متن کامل

Performance of Blood Glucose Meters in the Low-Glucose Range: Current Evaluations Indicate That it is not Sufficient From a Clinical Point of View.

System accuracy requirements for blood glucose (BG) meters (BGMs) are defined in standards (1) or guidance documents (2). In 2013, International Organization for Standardization (ISO) 15197:2013 stated that BGMs are acceptably accurate if $95% of their measurement results are found within 615 mg/dL (0.83 mmol/L) or 615% (whichever is larger) of reference results (1). The 2014 U.S. Food and Drug...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017